EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation

Teresa Laborda-Guirao, Christian Hierro-Cordón, José María Sánchez-González, Timoteo González-Cruces

Journal of Clinical Medicine · 17.11.2026 · 15 (22) · 8999

DOI: 10.3390/jcm15228999 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 17.11.2026. Verfasst von Teresa Laborda-Guirao und 3 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases.

Methods

We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation.

Results

R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of 50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid.

Conclusions

Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.

Zitieren

APA

Laborda-Guirao, T., Hierro-Cordón, C., Sánchez-González, J. M., & González-Cruces, T. (2026). Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation. Journal of Clinical Medicine, 15(22), 8999. https://doi.org/10.3390/jcm15228999

Vancouver

Laborda-Guirao T, Hierro-Cordón C, Sánchez-González JM, González-Cruces T. Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation. Journal of Clinical Medicine. 2026;15(22):8999. doi:10.3390/jcm15228999

BibTeX
@article{LabordaGuirao2026,
  author = {Laborda-Guirao, Teresa and Hierro-Cordón, Christian and Sánchez-González, José María and González-Cruces, Timoteo},
  title = {Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {8999},
  doi = {10.3390/jcm15228999}
}
Kostenlos starten →