EUVIMEDEUVIMED entdecken
Open Access

Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation

S Tamilarasi, Ashalyne James Joseph, Ramamurthy Dandapani

Indian Journal of Ophthalmology · 2024-04 · 72 (4) · 582-586

DOI: 10.4103/ijo.ijo_1386_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 23.02.2024. Verfasst von S Tamilarasi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cataract and Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India. Hauptthemen laut MEDLINE: Astigmatism, Phacoemulsification, Lenses, Intraocular, Corneal Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the predictive accuracy of Barrett total keratometry (Barrett TK) toric calculator with the measured posterior corneal astigmatism (PCA) by using Pentacam in toric intraocular lens (IOL) power calculation.

Methods

A prospective analysis was done on 118 eyes requiring toric IOL power implantation. The absolute prediction error of the Barrett TK toric calculator and the measured PCA in the online toric calculator were assessed and compared to the standard Alcon toric calculator (with Barrett toric calculator incorporated).

Results

The mean absolute prediction error of the online toric calculator (0.32 D) (with Barrett toric calculator incorporated), Barrett TK Toric (0.34 D), and measured PCA of Pentacam in Barrett toric calculator (0.33 D) were found to be similar with no statistically significant difference. Subanalysis in eyes with with-the-rule astigmatism, against-the-rule astigmatism, and oblique astigmatism showed similar results. Alpins analysis showed that all three methods overcorrected corneal astigmatism.

Conclusion

The Barrett TK toric calculator and the measured PCA of Pentacam in the Barrett toric calculator have similar predictive accuracy to the online toric calculator (with Barrett toric calculator incorporated).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismPhacoemulsificationLenses, IntraocularCorneal DiseasesHumansLens Implantation, IntraocularRefraction, OcularCorneaRetrospective StudiesBiometry

Autor:innen und Institutionen

  • Department of Cataract and Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India.

Zitieren

APA

Tamilarasi, S., Joseph, A. J., & Dandapani, R. (2024). Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation. Indian Journal of Ophthalmology, 72(4), 582-586. https://doi.org/10.4103/ijo.ijo_1386_23

Vancouver

Tamilarasi S, Joseph AJ, Dandapani R. Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation. Indian Journal of Ophthalmology. 2024;72(4):582-586. doi:10.4103/ijo.ijo_1386_23

BibTeX
@article{Tamilarasi2024,
  author = {Tamilarasi, S and Joseph, Ashalyne James and Dandapani, Ramamurthy},
  title = {Predictive accuracy of Barrett TK toric calculator compared to measured posterior corneal astigmatism using Pentacam in toric IOL power calculation},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  volume = {72},
  number = {4},
  pages = {582--586},
  doi = {10.4103/ijo.ijo_1386_23}
}
Kostenlos starten →