Local Diagnostic Reference Levels and Objective Image Quality in Mechanical Thrombectomy Performed with a Low-Dose Protocol: A Single-Center Observational Study

Mariusz Stanisław Sowa, Joanna Sowa, Maciej Budzanowski

Journal of Clinical Medicine · 12.11.2026 · 15 (22) · 8846

DOI: 10.3390/jcm15228846 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Journal of Clinical Medicine, online erschienen am 12.11.2026. Verfasst von Mariusz Stanisław Sowa und 2 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Minister of Science under the ‘Regional Initiative of Excellence Program’.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aims to establish local diagnostic reference levels (DRLs) for mechanical thrombectomy performed using a low-dose imaging protocol and to assess objective image quality parameters under routine clinical conditions.

Methods

This retrospective, single-center observational study included 59 consecutive patients who underwent mechanical thrombectomy for acute ischemic stroke between January 2023 and March 2026, with no exclusions. Radiation metrics, including dose-area product (DAP), reference air kerma (Ka,r), fluoroscopy time (FT), and number of images, were extracted from system-generated dose reports. Local DRLs were defined as the 75th percentile (P75) of the dose distribution. Objective image quality was assessed using quantitative parameters such as background noise, signal-to-noise ratio (SNR), absolute contrast-to-noise ratio (CNR), CNR/DAP, CNR/Ka,r, and figure-of-merit (FOM = CNR2/DAP).

Results

In the overall cohort, the median and P75 values were 16.6/26.2 Gy·cm2 for DAP, 206/306 mGy for Ka,r, and 1217/1622 s for FT. The median number of images per procedure was 210, with a P75 of 285. Procedures utilizing combined biplane imaging demonstrated higher DAP and Ka,r values compared to those using single-plane imaging, while FT did not differ significantly. Objective image-quality analysis was feasible in all 59 procedures. The median background noise, SNR, and absolute CNR were 44.24, 34.47, and 26.99, respectively. Median dose-normalized values were 1.32 for CNR/DAP, 0.12 for CNR/Ka,r, and 33.21 for FOM. No procedure required escalation of the imaging protocol due to insufficient angiographic visualization.

Conclusions

Mechanical thrombectomy performed under a predefined low-dose protocol yielded low absolute local dose values in this single-center cohort. ROI-based image-quality parameters remained measurable. Because no standard-dose comparator was imaged, the magnitude of dose reduction and the preservation of image quality relative to conventional settings could not be quantified.

Förderung

  • Minister of Science under the ‘Regional Initiative of Excellence Program’

Zitieren

APA

Sowa, M. S., Sowa, J., & Budzanowski, M. (2026). Local Diagnostic Reference Levels and Objective Image Quality in Mechanical Thrombectomy Performed with a Low-Dose Protocol: A Single-Center Observational Study. Journal of Clinical Medicine, 15(22), 8846. https://doi.org/10.3390/jcm15228846

Vancouver

Sowa MS, Sowa J, Budzanowski M. Local Diagnostic Reference Levels and Objective Image Quality in Mechanical Thrombectomy Performed with a Low-Dose Protocol: A Single-Center Observational Study. Journal of Clinical Medicine. 2026;15(22):8846. doi:10.3390/jcm15228846

BibTeX
@article{Sowa2026,
  author = {Sowa, Mariusz Stanisław and Sowa, Joanna and Budzanowski, Maciej},
  title = {Local Diagnostic Reference Levels and Objective Image Quality in Mechanical Thrombectomy Performed with a Low-Dose Protocol: A Single-Center Observational Study},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {8846},
  doi = {10.3390/jcm15228846}
}
Kostenlos starten →