Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent
Journal of Clinical Medicine · 08.11.2026 · 15 (21) · 8711
DOI: 10.3390/jcm15218711 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 08.11.2026. Verfasst von Yukari Suzuki und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo 135-8550, Japan. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The impact of initial stent type on endoscopic reintervention after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear.
Methods
We retrospectively evaluated patients with malignant biliary obstruction who developed recurrent biliary obstruction (RBO) after EUS-HGS and underwent reintervention through the endosonographically created route (ESCR). Outcomes were compared according to initial stent type (plastic stent [PS] or self-expandable metallic stent [SEMS]). The association between initial stent type and time to RBO (TRBO) after definitive biliary drainage was assessed using Cox regression and Fine–Gray regression.
Results
Of 170 patients who underwent EUS-HGS, 69 were included (PS, n = 23; SEMS, n = 46). The initial reintervention procedure was technically successful in 100% and 95.7% of patients, respectively (p = 0.55). Definitive biliary drainage was technically successful in all 69 patients, while clinical success was achieved in 62 (89.9%). No procedure-related adverse events were observed. Among patients with clinical success, median TRBO was 160 and 140 days in the PS and SEMS groups, respectively. Initial SEMS placement was not significantly associated with TRBO (adjusted hazard ratio, 1.32; 95% confidence interval [CI], 0.55–3.13) or the cumulative incidence of RBO (adjusted subdistribution hazard ratio, 1.67; 95% CI, 0.70–3.97).
Conclusions
Endoscopic reintervention through the ESCR was technically feasible after both initial PS and SEMS placement. Initial stent type was not significantly associated with subsequent RBO, although the findings should be interpreted cautiously because of potential temporal confounding and the limited sample size.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo 135-8550, Japan.
ORCID-Profile: Yukari Suzuki, Takashi Sasaki, Tsuyoshi Takeda, Yuri Maegawa, Takafumi Mie, Takeshi Okamoto, Naoki Sasahira
Zitieren
APA
Suzuki, Y., Sasaki, T., Takeda, T., Miura, M., Nagasawa, M., Saito, T., Maegawa, Y., Mie, T., Okamoto, T., Ozaka, M., & Sasahira, N. (2026). Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent. Journal of Clinical Medicine, 15(21), 8711. https://doi.org/10.3390/jcm15218711
Vancouver
Suzuki Y, Sasaki T, Takeda T, Miura M, Nagasawa M, Saito T, et al. Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent. Journal of Clinical Medicine. 2026;15(21):8711. doi:10.3390/jcm15218711
BibTeX
@article{Suzuki2026,
author = {Suzuki, Yukari and Sasaki, Takashi and Takeda, Tsuyoshi and Miura, Masashi and Nagasawa, Masanori and Saito, Toyokazu and Maegawa, Yuri and Mie, Takafumi and Okamoto, Takeshi and Ozaka, Masato and Sasahira, Naoki},
title = {Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {21},
pages = {8711},
doi = {10.3390/jcm15218711}
}
EUVIMED