EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty

Thomas L Bradbury iD, Charlotte C Baker iD, Zachary M Ricciardelli iD, Evan Bilson iD, Joseph M Schwab iD, George N Guild

Journal of Clinical Medicine · 17.08.2026 · 15 (16) · 6343

DOI: 10.3390/jcm15166343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 17.08.2026. Verfasst von Thomas L Bradbury und 5 weiteren Autor:innen. Beteiligte Einrichtung: Total Joint Specialists, Northside Hospital Forsyth, Cumming, GA 30041, USA. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zimmer Biomet (United States).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Collared triple-tapered cementless femoral stems are designed to optimize metaphyseal fit, stability, and osseointegration following total hip arthroplasty (THA). This study evaluated 90-day revision and complication rates, short-term functional recovery, and operative characteristics of a modern collared triple-tapered stem in a same-day discharge ambulatory surgery center cohort.

Methods

This retrospective cohort study reviewed 525 consecutive primary direct anterior THAs performed by 15 fellowship-trained arthroplasty surgeons at one group operating across several ASCs between September 2024 and August 2025. Ninety-day all-cause revision, stem-specific revision, periprosthetic fracture, and other early postoperative complications were evaluated. Kaplan–Meier estimates were used to account for variable follow-up within the 90 days. PROMs (HOOS-JR, FJS, VR-12) were collected preoperatively and at 12 weeks. Operative time was evaluated using within-surgeon analyses restricted to surgeons who used both an automated impaction device (AID) and manual impaction.

Results

At a mean effective follow-up of 110 ± 39 days, the 90-day Kaplan–Meier revision-free estimate was 99.62% for all-cause revision and 99.81% for stem revision. Two patients (0.4%) underwent revision (one Vancouver B2 fracture; one infection treated with DAIR with stem retention). The early periprosthetic fracture rate was 0.2%. Five patients (1.0%) experienced dislocation, all of whom were managed with closed reduction. HOOS-JR improved by 28.7 points and FJS by 41.9 points at 12 weeks (both p < 0.0001), with 84.2% and 85.8% MCID achievement, respectively. Seven surgeons used both techniques, contributing 384 AID and 58 manual cases to the within-surgeon analysis. AID use was not associated with operative time after accounting for surgeon (adjusted difference, 0.18 min; 95% CI, −2.04 to 2.39; p = 0.8764).

Conclusions

This collared, triple-tapered cementless stem was associated with low 90-day revision and complication rates and clinically meaningful short-term functional improvement in a same-day discharge ambulatory population. AID use was not associated with operative time after accounting for surgeon, although the study was not powered to compare uncommon complications between impaction methods.

Schlagwörter

Stichwörter der Autor:innen

automated impactorearly complicationstriple-taper stem

Autor:innen und Institutionen

  • Total Joint Specialists, Northside Hospital Forsyth, Cumming, GA 30041, USA.

ORCID-Profile: Thomas L Bradbury, Charlotte C Baker, Zachary M Ricciardelli, Evan Bilson, Joseph M Schwab

Förderung

  • Zimmer Biomet (United States)

Zitieren

APA

Bradbury, T. L., Baker, C. C., Ricciardelli, Z. M., Bilson, E., Schwab, J. M., & Guild, G. N. (2026). Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty. Journal of Clinical Medicine, 15(16), 6343. https://doi.org/10.3390/jcm15166343

Vancouver

Bradbury TL, Baker CC, Ricciardelli ZM, Bilson E, Schwab JM, Guild GN. Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty. Journal of Clinical Medicine. 2026;15(16):6343. doi:10.3390/jcm15166343

BibTeX
@article{Bradbury2026,
  author = {Bradbury, Thomas L and Baker, Charlotte C and Ricciardelli, Zachary M and Bilson, Evan and Schwab, Joseph M and Guild, George N},
  title = {Early Performance of a Collared, Triple-Tapered Cementless Femoral Stem in Primary Total Hip Arthroplasty},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {16},
  pages = {6343},
  doi = {10.3390/jcm15166343}
}
Kostenlos starten →