EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Association between cementless femoral stem geometry and early aseptic loosening following primary total hip arthroplasty

Regina Chi iD, Jawad J Najdawi, Andrew P Nakla iD, Rebecca G Burr iD, Sean S Rajaee

HIP International · 17.11.2026

DOI: 10.1177/11207000261490488 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HIP International, online erschienen am 17.11.2026. Verfasst von Regina Chi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, USA. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Aseptic loosening is a significant complication following total hip arthroplasty (THA), particularly in geriatric patients with diminished bone quality. Femoral stem design in cementless primary THA for osteoarthritis (OA) plays a crucial role in mitigating this risk. This study examined the impact of stem geometry on early aseptic loosening. We hypothesised that single-taper (wedge) stems are associated with higher rates of early aseptic loosening.

Methods

We retrospectively analysed 2952 cementless primary THA procedures at a single institution between November 2013 and December 2021. Patients ⩾ 65 years old who underwent primary THA for OA were included. Patients with preoperative diagnoses of fracture, avascular necrosis (AVN), or bone neoplasia, and those with periprosthetic fracture (PPF) within 90 days of index procedure were excluded. Femoral stems were categorised into 4 groups: (1) single-taper (wedge); (2A) collarless dual- and triple-taper; (2B) collared dual- and triple-taper; and (3) fit-and-fill. 2-year rates of femoral aseptic loosening as well as return to operating room (OR) were assessed.

Results

The study consisted of 1000 single-taper stems, 1185 collarless dual- and triple-taper stems, 213 collared dual- and triple-taper stems, and 554 fit-and-fill stems. Single-taper stems had significantly higher rates of aseptic loosening (0.8% vs. 0.2%) and overall return to the OR (2.6% versus 1.1%).

Conclusions

Single-taper stems demonstrated higher rates of return to the OR and revision for femoral aseptic loosening during the 2-year postoperative period. Surgeons should consider these findings when selecting femoral stem designs for elderly patients who plan to undergo cementless primary THA.

Schlagwörter

Stichwörter der Autor:innen

Aseptic looseningcementless femoral stemfemoral stem geometrytotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, USA.

ORCID-Profile: Regina Chi, Andrew P Nakla, Rebecca G Burr

Zitieren

APA

Chi, R., Najdawi, J. J., Nakla, A. P., Burr, R. G., & Rajaee, S. S. (2026). Association between cementless femoral stem geometry and early aseptic loosening following primary total hip arthroplasty. HIP International. https://doi.org/10.1177/11207000261490488

Vancouver

Chi R, Najdawi JJ, Nakla AP, Burr RG, Rajaee SS. Association between cementless femoral stem geometry and early aseptic loosening following primary total hip arthroplasty. HIP International. 2026. doi:10.1177/11207000261490488

BibTeX
@article{Chi2026,
  author = {Chi, Regina and Najdawi, Jawad J and Nakla, Andrew P and Burr, Rebecca G and Rajaee, Sean S},
  title = {Association between cementless femoral stem geometry and early aseptic loosening following primary total hip arthroplasty},
  journal = {HIP International},
  year = {2026},
  doi = {10.1177/11207000261490488}
}
Kostenlos starten →