Redefining Access: Transition from Conventional to Transaxillary Endoscopic Aortic Valve and Ascending Aorta Replacement—A Case Report with Literature Review
Journal of Clinical Medicine · 01.08.2026 · 15 (15) · 5996
DOI: 10.3390/jcm15155996 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Clinical Medicine, online erschienen am 01.08.2026. Verfasst von Tanja Josic und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Helios Hospital Siegburg, 53721 Siegburg, Germany. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Minimally invasive approaches for combined aortic valve and ascending aortic surgery remain challenging. We report a case of utilizing a transaxillary approach (TAX) in combination with the RAM® system.
Methods
A 65-year-old male presented with exertional angina and palpitations. He reported a one-year history of dizziness. Diagnostics revealed severe aortic regurgitation due to a calcified bicuspid aortic valve and an ascending aortic aneurysm measuring 57 × 54 mm. Left ventricular ejection fraction was reduced to 42%. Coronary artery disease was excluded. Surgery was performed via a right transaxillary mini-thoracotomy (3rd intercostal space) using endoscopic visualization. Cardiopulmonary bypass was established through femoral cannulation. After aortic cross-clamping and cardioplegic arrest, the bicuspid valve was excised and replaced with a bioprosthesis. A supracoronary ascending aortic replacement was performed using a Dacron graft. The RAM® system was used for annular suturing and proximal anastomosis, with automated fastener fixation.
Results
The patient was extubated on postoperative day 1 and transferred to intermediate care on day 2. Postoperative recovery was uneventful, with no neurological deficits, bleeding, or other complications. Discharge occurred on postoperative day 9 in stable condition.
Conclusions
This case highlights the feasibility and safety of a minimally invasive transaxillary approach for combined aortic valve and ascending aortic replacement using the RAM® system. This technique may expand the surgical armamentarium for complex aortic pathology while avoiding sternotomy. Further studies are required to evaluate reproducibility, long-term outcomes, and broader applicability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, Helios Hospital Siegburg, 53721 Siegburg, Germany.
Zitieren
APA
Josic, T., & Doss, M. (2026). Redefining Access: Transition from Conventional to Transaxillary Endoscopic Aortic Valve and Ascending Aorta Replacement—A Case Report with Literature Review. Journal of Clinical Medicine, 15(15), 5996. https://doi.org/10.3390/jcm15155996
Vancouver
Josic T, Doss M. Redefining Access: Transition from Conventional to Transaxillary Endoscopic Aortic Valve and Ascending Aorta Replacement—A Case Report with Literature Review. Journal of Clinical Medicine. 2026;15(15):5996. doi:10.3390/jcm15155996
BibTeX
@article{Josic2026,
author = {Josic, Tanja and Doss, Mirko},
title = {Redefining Access: Transition from Conventional to Transaxillary Endoscopic Aortic Valve and Ascending Aorta Replacement—A Case Report with Literature Review},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {15},
pages = {5996},
doi = {10.3390/jcm15155996}
}
EUVIMED