Agreement Between Automated Pedicle Screw Planning and Surgeon-Selected Implant Dimensions in Thoracic and Lumbar Spine Surgery: A Three-Year Single-Center Study
Journal of Clinical Medicine · 24.07.2026 · 15 (15) · 5804
DOI: 10.3390/jcm15155804 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 24.07.2026. Verfasst von Laura Herkner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Automated pedicle screw planning (ASP) can initialize trajectories and implant dimensions, but correlation with implanted screws does not establish agreement. We quantified the association and agreement between ASP recommendations and actual intraoperative implant selection (AIS) and examined pathology, asymmetric planning, and available safety outcomes.
Methods
This retrospective single-center study included 103 consecutive patients treated with thoracic or lumbar instrumentation from January 2021 to January 2024. The dataset contained 351 bilateral screw-pair records. Pearson and Spearman correlations, linear regression, and Bland–Altman analyses were supplemented by patient-clustered bootstrap 95% confidence intervals (CIs), pathology-stratified estimates, and a sensitivity analysis excluding a verified 94 mm iliac-fixation observation.
Results
Diameter showed moderate correlation (Pearson’s r = 0.635, 95% CI 0.542–0.721; Spearman’s rho = 0.679, 95% CI 0.554–0.767; both p < 0.001). Length also showed moderate correlation (Pearson’s r = 0.675, 95% CI 0.565–0.754; Spearman’s rho = 0.600, 95% CI 0.450–0.714; both p < 0.001). For ASP minus AIS, the diameter bias was −0.75 mm (95% CI −0.86 to −0.64), with limits of agreement from −2.00 to 0.50 mm. The length bias was −0.15 mm (95% CI −1.05 to 0.79), with limits from −12.30 to 12.00 mm. The 94 mm value was verified as a genuine iliac-fixation observation; excluding it changed Pearson’s r only from 0.675 to 0.679. Asymmetric ASP length recommendations occurred in 115/351 pairs (32.8%), usually by 5 mm.
Conclusions
ASP tracked overall implant-size trends but did not provide interchangeable estimates of surgeon-selected dimensions. Its systematic diameter underestimation and broad pair-level differences support its use as an initialization and review aid, with final sizing retained as a surgeon decision.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
- Department of Neurosurgery, Klinikum Ibbenbueren, Große Str. 41, 49477 Ibbenbueren, Germany.
ORCID-Profile: Joachim K Krauss
Zitieren
APA
Herkner, L., Hans, F. J., Stefan, M. L., Krauss, J. K., Al-Afif, S., & Ridwan, S. (2026). Agreement Between Automated Pedicle Screw Planning and Surgeon-Selected Implant Dimensions in Thoracic and Lumbar Spine Surgery: A Three-Year Single-Center Study. Journal of Clinical Medicine, 15(15), 5804. https://doi.org/10.3390/jcm15155804
Vancouver
Herkner L, Hans FJ, Stefan ML, Krauss JK, Al-Afif S, Ridwan S. Agreement Between Automated Pedicle Screw Planning and Surgeon-Selected Implant Dimensions in Thoracic and Lumbar Spine Surgery: A Three-Year Single-Center Study. Journal of Clinical Medicine. 2026;15(15):5804. doi:10.3390/jcm15155804
BibTeX
@article{Herkner2026,
author = {Herkner, Laura and Hans, Franz-Josef and Stefan, Mihail-Lucian and Krauss, Joachim K and Al-Afif, Shadi and Ridwan, Sami},
title = {Agreement Between Automated Pedicle Screw Planning and Surgeon-Selected Implant Dimensions in Thoracic and Lumbar Spine Surgery: A Three-Year Single-Center Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {15},
pages = {5804},
doi = {10.3390/jcm15155804}
}
EUVIMED