Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study
Asian Spine Journal · 31.10.2024 · 18 (5) · 663-672
DOI: 10.31616/asj.2024.0191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Asian Spine Journal, erschienen am 31.10.2024. Verfasst von Madhava Pai Kanhangad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Study Design: Prospective single-center study.
Purpose
To compare the accuracy of pedicle screws placed by freehand and under fluoroscopy and robotic assistance with intraoperative image acquisition.Overview of Literature: Pedicle screws are the most commonly used spinal anchors owing to their ability to stabilize all three spinal columns. Various techniques such as freehand, fluoroscopy-assisted, and navigation-assisted pedicle screw placements have been used with varying degrees of accuracy. Most studies on robotic-assisted pedicle screw placement have utilized preoperatively acquired computed tomography scans. To our knowledge, this is the only study in the literature that compared freehand with fluoroscopy-guided and robotic-assisted pedicle screw insertion with freehand and fluoroscopy.
Methods
In this prospective study, a total of 1,120 pedicle screws were placed in the freehand group (n=175), 1,250 in the fluoroscopyassisted group (n=172), and 1,225 in the robotic-assisted group (n=180). Surgical parameters and screw accuracy were analyzed between the three groups. The preoperative plan overlapped with the postoperative O-arm scan to determine if the screws were executed as planned.
Results
The frequency of clinically acceptable screw placement (Gertzbein-Robbins grades A and B) in the freehand, fluoroscopy-assisted, and robotic-assisted groups were 97.7%, 98.6%, and 99.34%, respectively. With robotic assistance, an experience-neutralizing effect implied that surgeons with varying levels of experience achieved comparable pedicle screw accuracy, blood loss, O-arm time, robot time, and time per screw. No significant difference in these parameters was found between surgeries commencing before and after 2 PM. No significant differences were noted between the planned and executed screw trajectories in the robotic-assisted group irrespective of surgical experience.
Conclusions
The third-generation robotic-assisted pedicle screw placement system used in conjunction with intraoperative threedimensional O-arm imaging consistently demonstrates safe and accurate screw placement with an experience-neutralizing effect.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Manipal Institute of Robotic Spine Surgery, Manipal Comprehensive Spine Care Centre, Manipal Hospital, Bangalore, India.
- Department of Orthopaedics, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, India.
- Department of Spine Anesthesia, Manipal Comprehensive Spine Care Center, Manipal Hospital, Bangalore, India.
- Department of Anesthesiology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, India.
Zitieren
APA
Kanhangad, M. P., Srinivasa, V., Thirugnanam, B., Soni, A., Kashyap, A., Vidyadhara, A., & Rao, S. K. (2024). Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study. Asian Spine Journal, 18(5), 663-672. https://doi.org/10.31616/asj.2024.0191
Vancouver
Kanhangad MP, Srinivasa V, Thirugnanam B, Soni A, Kashyap A, Vidyadhara A, et al. Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study. Asian Spine Journal. 2024;18(5):663-672. doi:10.31616/asj.2024.0191
BibTeX
@article{Kanhangad2024,
author = {Kanhangad, Madhava Pai and Srinivasa, Vidyadhara and Thirugnanam, Balamurugan and Soni, Abhishek and Kashyap, Anjana and Vidyadhara, Alia and Rao, Sharath Kumar},
title = {Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study},
journal = {Asian Spine Journal},
year = {2024},
volume = {18},
number = {5},
pages = {663--672},
doi = {10.31616/asj.2024.0191}
}
EUVIMED