Clinical Outcomes and Complications After INTACS Implantation in Keratoconus: A Systematic Review
Journal of Clinical Medicine · 25.05.2026 · 15 (11) · 4076
DOI: 10.3390/jcm15114076 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 25.05.2026. Verfasst von Wiktoria Czuj-Porębska und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, District Railway Hospital in Katowice, Medical University of Silesia, 40-760 Katowice, Poland. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of Silesia.
Abstract (Originalsprache)
Background/Objectives: Keratoconus is a progressive corneal ectatic disorder leading to irregular astigmatism and visual impairment. INTACS intracorneal ring segments are used to improve corneal shape and visual function; however, postoperative complications may occur. A comprehensive and evidence-based evaluation of visual outcomes and complications after INTACS implantation is therefore warranted.
Methods
PubMed, Scopus, and Google Scholar were searched for English-language articles published between January 2015 and December 2025 using the terms INTACS, intracorneal ring segments, keratoconus, and complications, following a systematic literature search conducted in accordance with PRISMA 2020 guidelines. Only studies reporting INTACS-specific outcomes were included. Studies evaluating other intracorneal ring systems were excluded unless INTACS data could be separately extracted.
Results
Seventeen studies comprising 544 eyes were included. INTACS implantation was associated with consistent improvements in visual acuity and corneal parameters. However, clinically relevant device-related complications, including segment migration, extrusion, and the need for secondary procedures such as repositioning or explantation, remain an important limitation. These findings indicate that although INTACS is an effective corneal regularization strategy, long-term safety depends on careful patient selection, precise surgical technique, and close postoperative surveillance.
Conclusions
INTACS implantation is an effective option for visual rehabilitation in patients with keratoconus; however, its long-term safety is limited by the risk of device-related complications. Careful patient selection, appropriate surgical technique, and structured postoperative follow-up are essential to optimize outcomes and minimize adverse events.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, District Railway Hospital in Katowice, Medical University of Silesia, 40-760 Katowice, Poland.
- Experimental Ophthalmology Unit, Department of Biophysics, Railway Hospital in Katowice, Medical University of Silesia, 40-760 Katowice, Poland.
- Department of Ophthalmology, Faculty of Medical Sciences, School of Medicine in Zabrze, Medical University of Silesia, 40-760 Katowice, Poland.
ORCID-Profile: Wiktoria Czuj-Porębska, Adam Wylęgała, Anna Martyka, Edward Wylęgała
Förderung
- Medical University of Silesia
Zitieren
APA
Czuj-Porębska, W., Wylęgała, A., Martyka, A., Gospodarczyk, N., Piłat, J., Wylęgała, E., & Wowra, B. (2026). Clinical Outcomes and Complications After INTACS Implantation in Keratoconus: A Systematic Review. Journal of Clinical Medicine, 15(11), 4076. https://doi.org/10.3390/jcm15114076
Vancouver
Czuj-Porębska W, Wylęgała A, Martyka A, Gospodarczyk N, Piłat J, Wylęgała E, et al. Clinical Outcomes and Complications After INTACS Implantation in Keratoconus: A Systematic Review. Journal of Clinical Medicine. 2026;15(11):4076. doi:10.3390/jcm15114076
BibTeX
@article{CzujPorbska2026,
author = {Czuj-Porębska, Wiktoria and Wylęgała, Adam and Martyka, Anna and Gospodarczyk, Natalia and Piłat, Jarosław and Wylęgała, Edward and Wowra, Bogumił},
title = {Clinical Outcomes and Complications After INTACS Implantation in Keratoconus: A Systematic Review},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {11},
pages = {4076},
doi = {10.3390/jcm15114076}
}
EUVIMED