Preliminary Validation of the Italian Version of the Artificially Intelligent Device Use Acceptance (AIDUA-IT) Scale: Cross-Cultural Adaptation and Psychometric Evaluation
Journal of Clinical Medicine · 17.02.2026 · 15 (4) · 1578
DOI: 10.3390/jcm15041578 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 17.02.2026. Verfasst von Giulia Cavasin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Pulmonology Unit, Ca' Foncello Hospital, Azienda ULSS 2 Marca Trevigiana, 31100 Treviso, Italy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Artificial intelligence (AI) is increasingly integrated into healthcare and public services, making user acceptance a key prerequisite for safe and effective implementation. The Artificially Intelligent Device Use Acceptance (AIDUA) model provides a multidimensional framework for evaluating acceptance of intelligent systems, yet no validated Italian instrument is currently available.
Objectives
This study aimed to translate, culturally adapt, and preliminarily validate the Italian version of the AIDUA scale (AIDUA-IT) following COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) recommendations.
Methods
A two-phase cross-sectional design was used. Phase one included forward–backward translation, expert review (n = 7), and cognitive debriefing (n = 8). Phase two assessed structural validity, internal consistency, convergent and discriminant validity, and short-term test–retest reliability in a convenience sample of Italian-speaking adults (N = 140), with a subsample completing the test–retest assessment (n = 32).
Results
The hypothesized eight-factor measurement model demonstrated excellent fit (Comparative Fit Index [CFI] = 0.984; Tucker–Lewis Index [TLI] = 0.981; Root Mean Square Error of Approximation [RMSEA] = 0.041; Standardized Root Mean Square Residual [SRMR] = 0.056), with strong standardized loadings (β range: 0.64–0.96) and good internal consistency (Cronbach’s α and McDonald’s ω range: 0.82–0.90). Convergent and discriminant validity were supported, and test–retest reliability was good to excellent across subscales (Intraclass Correlation Coefficient [ICC] range: 0.81–0.90).
Conclusions
These findings provide initial evidence that the AIDUA-IT is a reliable and valid instrument for assessing acceptance of AI-enabled services in Italy. Further validation in larger and more diverse samples is recommended.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pulmonology Unit, Ca' Foncello Hospital, Azienda ULSS 2 Marca Trevigiana, 31100 Treviso, Italy.
- Unit of Biostatistics, Epidemiology and Public Health, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Via Loredan 18, 35121 Padova, Italy.
- Biostatistics & AI for Biomedical Discovery (BIOSTAT-X), Pediatric Research Institute (IRP) "Città della Speranza", 35127 Padova, Italy.
ORCID-Profile: Giulia Cavasin, Honoria Ocagli, Dario Gregori
Zitieren
APA
Cavasin, G., Ocagli, H., & Gregori, D. (2026). Preliminary Validation of the Italian Version of the Artificially Intelligent Device Use Acceptance (AIDUA-IT) Scale: Cross-Cultural Adaptation and Psychometric Evaluation. Journal of Clinical Medicine, 15(4), 1578. https://doi.org/10.3390/jcm15041578
Vancouver
Cavasin G, Ocagli H, Gregori D. Preliminary Validation of the Italian Version of the Artificially Intelligent Device Use Acceptance (AIDUA-IT) Scale: Cross-Cultural Adaptation and Psychometric Evaluation. Journal of Clinical Medicine. 2026;15(4):1578. doi:10.3390/jcm15041578
BibTeX
@article{Cavasin2026,
author = {Cavasin, Giulia and Ocagli, Honoria and Gregori, Dario},
title = {Preliminary Validation of the Italian Version of the Artificially Intelligent Device Use Acceptance (AIDUA-IT) Scale: Cross-Cultural Adaptation and Psychometric Evaluation},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {4},
pages = {1578},
doi = {10.3390/jcm15041578}
}
EUVIMED