EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element Analysis

Sergio Olate iD, Víctor Ravelo iD, Henry García Guevara iD, Roberto Sacco iD, Marcelo Parra, Marcio de Moraes

Journal of Clinical Medicine · 12.02.2026 · 15 (4) · 1436

DOI: 10.3390/jcm15041436 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 12.02.2026. Verfasst von Sergio Olate und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, Division of Oral and Maxillofacial Surgery, Faculty of Dentistry, State University of Campinas, Piracicaba 13414-018, S…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mandibular advancement is a commonly performed surgical procedure for the treatment of mandibular retrognathia and Class II dentofacial deformities; however, large advancements impose increased mechanical demands on fixation systems. Despite the availability of various fixation strategies, standard straight plate systems remain widely used worldwide due to their availability, cost-effectiveness, and clinical familiarity. Continuous biomechanical evaluation of these systems is therefore required to optimize stability and performance under demanding conditions.

Objectives

The aim of this study was to evaluate the influence of plate design, plate thickness, and fixation architecture on the mechanical stability of mandibular advancement using finite element analysis.

Methods

A three-dimensional finite element model simulating a unilateral mandibular osteotomy with a 10 mm gap was generated as mandibular advancement was developed. Fifteen fixation configurations were analyzed, including variations in plate design (simple and reinforced plates with partial or total inferior mesh extension), plate thickness (0.8 mm and 1.0 mm), and fixation architecture using independent plate systems (LN) or integrated fixation systems (FM). A vertical load was applied to the lower central incisor to simulate functional loading. Outcome measures included global equivalent stress considering screws and plate, equivalent stress within the plate, and global deformation of the fixation system.

Results

The analyses demonstrated distinct mechanical behaviors among the evaluated configurations. Differences in stress distribution and deformation were observed according to plate design, thickness, and fixation architecture. Reinforced designs, increased plate thickness, and integrated fixation systems showed reduced deformation and more favorable stress distribution when compared with simple plate configurations.

Conclusions

Plate design, thickness, and fixation architecture influenced the mechanical stability of mandibular advancement, supporting the importance of biomechanical optimization of standard fixation systems, particularly in large mandibular advancements.

Schlagwörter

Stichwörter der Autor:innen

internal rigid fixationorthognathic surgeryplate

Autor:innen und Institutionen

  • Department of Oral Diagnosis, Division of Oral and Maxillofacial Surgery, Faculty of Dentistry, State University of Campinas, Piracicaba 13414-018, SP, Brazil.
  • Center of Excellence in Morphological and Surgical Studies (CEMyQ), Universidad de La Frontera, Temuco 4811230, Chile.
  • Doctoral Program in Morphological Sciences, Universidad de La Frontera, Temuco 4811230, Chile.
  • Facultad Ciencias de la Salud, Universidad Autónoma de Chile, Temuco 4810101, Chile.
  • Division for Oral and Maxillofacial Surgery, Hospital Ortopedico Infantil, Caracas 1060, Venezuela.
  • Department of Oral Surgery, La Floresta Medical Institute, Caracas 1060, Venezuela.

ORCID-Profile: Sergio Olate, Víctor Ravelo, Henry García Guevara, Roberto Sacco

Zitieren

APA

Olate, S., Ravelo, V., García Guevara, H., Sacco, R., Parra, M., & de Moraes, M. (2026). Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element Analysis. Journal of Clinical Medicine, 15(4), 1436. https://doi.org/10.3390/jcm15041436

Vancouver

Olate S, Ravelo V, García Guevara H, Sacco R, Parra M, de Moraes M. Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element Analysis. Journal of Clinical Medicine. 2026;15(4):1436. doi:10.3390/jcm15041436

BibTeX
@article{Olate2026,
  author = {Olate, Sergio and Ravelo, Víctor and García Guevara, Henry and Sacco, Roberto and Parra, Marcelo and de Moraes, Marcio},
  title = {Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element Analysis},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {4},
  pages = {1436},
  doi = {10.3390/jcm15041436}
}
Kostenlos starten →