EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Cardiac Implantable Electronic Device-Related Infective Endocarditis Caused by Bacillus cereus: A Case Report

Denis Swolana iD, Danuta Łoboda iD, Beata Sarecka-Hujar iD, Rafał Sznajder, Anna Szajerska-Kurasiewicz, Tadeusz Zębik, Krzysztof S Gołba iD, Robert D Wojtyczka iD

Journal of Clinical Medicine · 02.01.2026 · 15 (1) · 344

DOI: 10.3390/jcm15010344 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Clinical Medicine, online erschienen am 02.01.2026. Verfasst von Denis Swolana und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 4 Jagiellońska Str., 41-200 S…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Agency, Poland, Medical University of Silesia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Globalization, increased mobility, changes in dietary habits, and a growing number of immunocompromised patients have heightened exposure to rare or opportunistic pathogens. Here, we present a case of cardiac implantable electronic device-related infective endocarditis (CIED-IE) caused by Bacillus cereus bacteremia originating in the gastrointestinal tract. Case presentation: A 66-year-old female, who had a cardiac resynchronization pacemaker (CRT-P) implanted in 2017 due to second-degree atrioventricular block and left bundle branch block, had undergone device replacement due to battery depletion 4 months earlier and was scheduled for transvenous lead extraction (TLE) due to generator pocket infection. During the TLE procedure, transoesophageal echocardiography revealed vegetations on the leads and in the right atrium. Standard empirical therapy covering methicillin-resistant Staphylococci and Gram-negative bacteria was administered, including oritavancin and gentamicin. Surprisingly, intraoperative samples cultured B. cereus, a Gram-positive, spore-forming rod that usually causes food poisoning through contamination of rice and other starchy foods. B. cereus is generally resistant to β-lactam antibiotics except for carbapenems but is susceptible to glycopeptides. The oritavancin treatment was extended to four fractionated doses (1200, 800, 800, and 800 mg) administered at 7-day intervals. To eradicate bacteria in the gastrointestinal tract, oral vancomycin (125 mg 4 times a day) was added. After 4 weeks of effective antibiotic therapy, a CRT-P with a left bundle branch area pacing lead was reimplanted on the right subclavian area, with no recurrence of infection during the 3-month follow-up. Clinical discussion: In the patient, a diet high in rice and improper storage of rice dishes, together with habitual constipation, were identified as risk factors for the development of invasive Bacillus cereus infection. However, the long half-life lipoglycopeptide antibiotic, oritavancin, administered weekly, proved effective in treating CIED-IE.

Conclusions

Infection with rare or opportunistic microorganisms may require extended microbiological diagnostics and non-standard antibiotic therapy; therefore, the medical history should consider risk factors for such infections.

Schlagwörter

Stichwörter der Autor:innen

Gram-positive bacterial infectionscardiac implantable electronic devicecase reportinfective endocarditispocket infection

Autor:innen und Institutionen

  • Department of Microbiology, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 4 Jagiellońska Str., 41-200 Sosnowiec, Poland.
  • Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, 45/47 Ziołowa Str., 40-635 Katowice, Poland.
  • Department of Electrocardiology and Heart Failure, Faculty of Health Sciences in Katowice, Medical University of Silesia in Katowice, 45/47 Ziołowa Str., 40-635 Katowice, Poland.
  • Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 8b Jedności Str., 41-200 Sosnowiec, Poland.
  • Department of Cardiology, Municipal Hospital in Gliwice, 29 Kosciuszki Str., 44-100 Gliwice, Poland.

ORCID-Profile: Denis Swolana, Danuta Łoboda, Beata Sarecka-Hujar, Krzysztof S Gołba, Robert D Wojtyczka

Förderung

  • Medical Research Agency, Poland
  • Medical University of Silesia

Zitieren

APA

Swolana, D., Łoboda, D., Sarecka-Hujar, B., Sznajder, R., Szajerska-Kurasiewicz, A., Zębik, T., Gołba, K. S., & Wojtyczka, R. D. (2026). Cardiac Implantable Electronic Device-Related Infective Endocarditis Caused by Bacillus cereus: A Case Report. Journal of Clinical Medicine, 15(1), 344. https://doi.org/10.3390/jcm15010344

Vancouver

Swolana D, Łoboda D, Sarecka-Hujar B, Sznajder R, Szajerska-Kurasiewicz A, Zębik T, et al. Cardiac Implantable Electronic Device-Related Infective Endocarditis Caused by Bacillus cereus: A Case Report. Journal of Clinical Medicine. 2026;15(1):344. doi:10.3390/jcm15010344

BibTeX
@article{Swolana2026,
  author = {Swolana, Denis and Łoboda, Danuta and Sarecka-Hujar, Beata and Sznajder, Rafał and Szajerska-Kurasiewicz, Anna and Zębik, Tadeusz and Gołba, Krzysztof S and Wojtyczka, Robert D},
  title = {Cardiac Implantable Electronic Device-Related Infective Endocarditis Caused by Bacillus cereus: A Case Report},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {1},
  pages = {344},
  doi = {10.3390/jcm15010344}
}