EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical profile and outcomes among patients with cardiac implantable electronic device presenting as isolated pocket infection, pocket-related infective endocarditis, or lead-related infective endocarditis

Wojciech Jacheć iD, Anna Polewczyk iD, Dorota Nowosielecka iD, Andrzej Kutarski iD

Europace · 28.03.2025 · 27 (4)

DOI: 10.1093/europace/euaf053 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 14.03.2025. Verfasst von Wojciech Jacheć und 3 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Poland. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Defibrillators, Implantable, Pacemaker, Artificial, Endocarditis. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of Silesia Katowice, Poland scientific.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The clinical spectrum of cardiac implantable electronic device (CIED) infections includes isolated pocket infection (IPI), pocket infection complicated by infective endocarditis (PIRIE), and lead-related infective endocarditis (LRIE). The aim of this study was to assess the risk factors, clinical course, and outcomes in patients with CIED infections and to demonstrate differences between PIRIE and LRIE. Methods and results The retrospective analysis of data from 3847 patients undergoing transvenous lead extraction for non-infectious (2640; 68.62%) and infectious (1207; 31.38%) indications, including 361 (29.91%) IPI, 472 (39.11%) PIRIE, and 374 (30.99%) LRIE, showed some differences in risk factors, clinical course, and outcomes between the subgroups. Unlike PIRIE, diabetes [hazard ratio (HR) = 1.488; 95% confidence interval (CI; 1.178–1.879), P < 0.001] and lead abrasion [HR = 2.117; 95% CI (1.665–2.691), P < 0.001] increased the risk of LRIE. The risk of pocket infection spread was greater with Staphylococcus aureus infection [HR = 1.596; 95% CI (1.202–2.120), P < 0.001]. Compared with LRIE, patients with PIRIE had lower levels of inflammatory markers and lower prevalence of vegetations. Mortality in PIRIE compared with LRIE patients was lower (53.18 vs. 62.30%; P < 0.001) and comparable to IPI (50.69%; P = 0.162) at long-term [median 1828 (815–3139) days] follow-up.

Conclusion

Cardiac implantable electronic device infections share common risk factors; however, diabetes and intra-cardiac lead abrasion predispose to LRIE, whereas multiple leads and S. aureus in pocket culture are risk factors for pocket infection spread. Compared with LRIE, the clinical course of PIRIE was milder, and short- and long-term mortalities were lower, but comparable with IPI after >1 year. This may be an argument in favour of categorization into primary LRIE and secondary endocarditis, i.e. PIRIE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsDefibrillators, ImplantablePacemaker, ArtificialEndocarditisEndocarditis, BacterialHumansMaleFemaleRetrospective StudiesMiddle AgedAgedRisk FactorsDevice RemovalTreatment OutcomeStaphylococcal Infections

Stichwörter der Autor:innen

Isolated pocket infectionPocket infection complicated by infective endocarditis

Autor:innen und Institutionen

  • 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Poland.
  • Institute of Medical Sciences, Jan Kochanowski University Kielce, 5, Żeromskiego St, 25-369 Kielce, Poland.
  • Department of Cardiac Surgery, Świętokrzyskie Cardiology Center, Kielce, Poland.
  • Department of Cardiology, The Pope John Paul II Province Hospital, Zamość, Poland.
  • Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland.

ORCID-Profile: Wojciech Jacheć, Anna Polewczyk, Dorota Nowosielecka, Andrzej Kutarski

Förderung

  • Medical University of Silesia Katowice, Poland scientific

Zitieren

APA

Jacheć, W., Polewczyk, A., Nowosielecka, D., & Kutarski, A. (2025). Clinical profile and outcomes among patients with cardiac implantable electronic device presenting as isolated pocket infection, pocket-related infective endocarditis, or lead-related infective endocarditis. Europace, 27(4). https://doi.org/10.1093/europace/euaf053

Vancouver

Jacheć W, Polewczyk A, Nowosielecka D, Kutarski A. Clinical profile and outcomes among patients with cardiac implantable electronic device presenting as isolated pocket infection, pocket-related infective endocarditis, or lead-related infective endocarditis. Europace. 2025;27(4). doi:10.1093/europace/euaf053

BibTeX
@article{Jache2025,
  author = {Jacheć, Wojciech and Polewczyk, Anna and Nowosielecka, Dorota and Kutarski, Andrzej},
  title = {Clinical profile and outcomes among patients with cardiac implantable electronic device presenting as isolated pocket infection, pocket-related infective endocarditis, or lead-related infective endocarditis},
  journal = {Europace},
  year = {2025},
  volume = {27},
  number = {4},
  doi = {10.1093/europace/euaf053}
}
Kostenlos starten →