Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 15.12.2025. Verfasst von Sriharsha Talapaneni und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, CT 06510, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Prosthesis–patient mismatch (PPM) occurs after aortic valve replacement (AVR) when the effective orifice area of the implanted prosthetic valve is small relative to the patient’s body surface area. Beyond simply elevating transvalvular gradient, PPM profoundly affects cardiac remodeling, coronary physiology, and ultimately patient survival. This comprehensive review synthesizes current evidence regarding PPM pathophysiology, clinical consequences, and therapeutic strategies.

Methods

We conducted a narrative review of PPM in surgical (SAVR) and transcatheter (TAVR) aortic valve replacement. PubMed and Embase were systematically searched using terms related to AVR and PPM and reference lists of key studies and reviews were screened. Studies addressing PPM prevalence, hemodynamic impact, clinical outcomes, and mitigation strategies were included.

Results

PPM, defined as an iEOA ≤ 0.85 cm2/m2 (moderate) or ≤0.65 cm2/m2 (severe), demonstrates variable prevalence across studies, typically ranging from 5 to 30% after SAVR and 2–35% after TAVR. It is associated with increased transvalvular gradients, reduced left ventricular mass regression, persistent coronary flow abnormalities, higher rates of heart failure, and both early and late mortality. Supra-annular self-expanding transcatheter aortic valve replacement (TAVR) devices and newer generation stentless or bovine pericardial surgical valves exhibit lower PPM rates than older stented or porcine valves. Valve-in-valve (ViV) TAVR and bioprosthetic valve fracture (BVF) can improve outcomes in failed surgical valves but are less effective in small annuli. TAVR-in-TAVR procedures are limited by anatomic and technical constraints, especially in maintaining coronary access and minimizing residual gradients.

Conclusions

PPM remains a common and clinically consequential complication of AVR that compromises long-term outcomes. It is largely preventable through accurate preoperative imaging, valve sizing, and consideration of annular enlargement. Optimal outcomes require matching valve characteristics to individual patient anatomy and physiology. In an era of expanding TAVR use, preventing PPM during the index procedure is critical to optimizing survival and preserving future reintervention options.

Schlagwörter

Stichwörter der Autor:innen

aortic stenosisaortic valve replacementpatient prosthesis mismatch (PPM)

Autor:innen und Institutionen

  • Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, CT 06510, USA.

ORCID-Profile: Pooya Jalali, Nafiye Busra Celik, Sair Ahmad Tabraiz, Irbaz Hameed

Zitieren

APA

Talapaneni, S., Ahmad, D., Khandelwal, M., Mesiha, M., Jalali, P., Celik, N. B., Tabraiz, S. A., Dankwa, S., Hameed, I., Milewski, R., & Vallabhajosyula, P. (2025). Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive Review. Journal of Clinical Medicine, 14(24), 8868. https://doi.org/10.3390/jcm14248868

Vancouver

Talapaneni S, Ahmad D, Khandelwal M, Mesiha M, Jalali P, Celik NB, et al. Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive Review. Journal of Clinical Medicine. 2025;14(24):8868. doi:10.3390/jcm14248868

BibTeX
@article{Talapaneni2025,
  author = {Talapaneni, Sriharsha and Ahmad, Danial and Khandelwal, Meghna and Mesiha, Monica and Jalali, Pooya and Celik, Nafiye Busra and Tabraiz, Sair Ahmad and Dankwa, Sedem and Hameed, Irbaz and Milewski, Rita and Vallabhajosyula, Prashanth},
  title = {Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive Review},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {24},
  pages = {8868},
  doi = {10.3390/jcm14248868}
}
Kostenlos starten →