EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The Impact of Prosthesis-Patient Mismatch on Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement

Revathy Sampath-Kumar, Erika Padilla, David Torres Barba, Niki Aramburo, Ori Ben-Yehuda, Ehtisham Mahmud

Structural Heart · 2026-01 · 10 (1) · 100741

DOI: 10.1016/j.shj.2025.100741 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Structural Heart, 2026-01. Verfasst von Revathy Sampath-Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Prosthesis-patient mismatch (PPM) is associated with structural valve deterioration after surgical aortic valve replacement. Limited evidence exists regarding its impact on hemodynamic valve deterioration (HVD) and bioprosthetic valve failure (BVF) following transcatheter aortic valve replacement (TAVR).

Methods

Patients who underwent TAVR from 2013 to 2022 at UC San Diego Health with echocardiographic follow-up were retrospectively analyzed. PPM, determined by measured indexed effective orifice area, and outcomes of moderate or severe HVD and BVF were defined per Valve Academic Research Consortium 3 guidelines. Fine and Gray regression, with all-cause death as a competing risk, was used to compare the cumulative incidence of outcomes in patients with and without PPM.

Results

A total of 555 patients (38.7% female, median age 81 years, median Society of Thoracic Surgeons risk score 4.2%, 96.8% balloon-expandable valves) were included. PPM occurred in 66 (11.9%) patients and was associated with higher initial post-implant mean gradient (15 mmHg IQR: 10-22 vs. 11 mmHg IQR: 8-15; p < 0001) and peak velocity (2.6 m/s IQR: 2.2-3.2 vs. 2.3 m/s IQR: 1.9-2.6; p < 0.001). Valve-in-valve TAVR (adjusted odds ratio: 7.84; 95% CI: 3.37-18.20; p < 0.001) and valve diameter ≤23 mm (adjusted odds ratio: 2.39; 95% CI: 1.12-5.10; p = 0.024) were independent predictors of PPM. The adjusted cumulative incidence of moderate or severe HVD (adjusted hazard ratio: 2.10; 95% CI: 1.02-4.30; p = 0.04) and BVF (adjusted hazard ratio: 4.32; 95% CI: 1.81-10.31; p = 0.001) was higher with PPM. Aortic valve reintervention was higher with PPM (4.5 vs. 0.6%; p = 0.03).

Conclusions

In this single-center cohort, PPM was associated with an over two-fold increased risk of moderate or severe HVD and an over four-fold increased risk of BVF following TAVR, emphasizing the importance of pre-implant prevention.

Schlagwörter

Stichwörter der Autor:innen

Hemodynamic valve deteriorationProsthesis-patient mismatchTranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Division of Cardiovascular Medicine, University of California San Diego, La Jolla, California, USA.

Zitieren

APA

Sampath-Kumar, R., Padilla, E., Barba, D. T., Aramburo, N., Ben-Yehuda, O., & Mahmud, E. (2026). The Impact of Prosthesis-Patient Mismatch on Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement. Structural Heart, 10(1), 100741. https://doi.org/10.1016/j.shj.2025.100741

Vancouver

Sampath-Kumar R, Padilla E, Barba DT, Aramburo N, Ben-Yehuda O, Mahmud E. The Impact of Prosthesis-Patient Mismatch on Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement. Structural Heart. 2026;10(1):100741. doi:10.1016/j.shj.2025.100741

BibTeX
@article{SampathKumar2026,
  author = {Sampath-Kumar, Revathy and Padilla, Erika and Barba, David Torres and Aramburo, Niki and Ben-Yehuda, Ori and Mahmud, Ehtisham},
  title = {The Impact of Prosthesis-Patient Mismatch on Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement},
  journal = {Structural Heart},
  year = {2026},
  volume = {10},
  number = {1},
  pages = {100741},
  doi = {10.1016/j.shj.2025.100741}
}
Kostenlos starten →