Comparative Biomechanical Evaluation of Bicortical Screw Versus Plate Fixation in Jones Fractures of the Fifth Metatarsal Using 3D-Printed Models
Journal of Clinical Medicine · 21.10.2025 · 14 (20) · 7449
DOI: 10.3390/jcm14207449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 21.10.2025. Verfasst von Robert Daniel Dobrotă und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 37 Dionisie Lupu Street, 020021 Bucharest, Romania. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Jones fractures of the 5th metatarsal are frequently associated with nonunion due to limited vascularization and repetitive mechanical stress. The aim of the study was to compare the biomechanical performance of T-plate and bicortical screw fixation using standardized 3D models.
Methods
Three-dimensional models of the 5th metatarsal were generated from CT images and printed using PolyJet technology (Stratasys J5 DentaJet) using a rigid-elastic composite with properties similar to cortical and cancellous bone. Jones fractures were fixed with either a locked T-plate or a bicortical screw. The samples were tested under axial and oblique static loads (α = 0°, 90°, 180°) and for three values of interfragmentary distance (d = 0.1–1 mm), in a 3 × 2 factorial design.
Results
The T-plate fixation recorded a maximum yield force (Fmax) of 149.78 ± 8.53 N (138–161 N), significantly higher compared to the bicortical screw −98.56 ± 2.58 N (96–101 N), (p < 0.05). The ductility index was higher for the plate, indicating a progressive transition to yield. The α and d factors significantly influenced the mechanical behavior, with the polynomial model explaining over 95% of the total variation.
Discussion
The plate fixation demonstrated greater strength and superior biomechanical tolerance in imperfect reduction scenarios. The main limitation is the lack of fatigue testing and the inability of 3D models to reproduce the structural heterogeneity of human bone.
Conclusions
Implant selection should be individualized based on fracture stability. 3D models provide a reproducible platform for comparative evaluation of osteosynthesis methods, but future studies should include cyclic loading and biological validation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 37 Dionisie Lupu Street, 020021 Bucharest, Romania.
- Dr. Carol Davila Central University Emergency Military Hospital, 010825 Bucharest, Romania.
- Faculty of Medicine, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania.
ORCID-Profile: Robert Daniel Dobrotă, Mark Pogărășteanu, Ioana-Codruța Lebada
Zitieren
APA
Dobrotă, R. D., Pogărășteanu, M., Ferechide, D., Lebada, I. C., & Moga, M. (2025). Comparative Biomechanical Evaluation of Bicortical Screw Versus Plate Fixation in Jones Fractures of the Fifth Metatarsal Using 3D-Printed Models. Journal of Clinical Medicine, 14(20), 7449. https://doi.org/10.3390/jcm14207449
Vancouver
Dobrotă RD, Pogărășteanu M, Ferechide D, Lebada IC, Moga M. Comparative Biomechanical Evaluation of Bicortical Screw Versus Plate Fixation in Jones Fractures of the Fifth Metatarsal Using 3D-Printed Models. Journal of Clinical Medicine. 2025;14(20):7449. doi:10.3390/jcm14207449
BibTeX
@article{Dobrot2025,
author = {Dobrotă, Robert Daniel and Pogărășteanu, Mark and Ferechide, Dumitru and Lebada, Ioana-Codruța and Moga, Marius},
title = {Comparative Biomechanical Evaluation of Bicortical Screw Versus Plate Fixation in Jones Fractures of the Fifth Metatarsal Using 3D-Printed Models},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {20},
pages = {7449},
doi = {10.3390/jcm14207449}
}
EUVIMED