EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of XEN45 Gel Stent Outcomes in Glaucoma: Ab Externo Open-Conjunctiva Approach with Ologen vs. Ab Interno Closed-Conjunctiva Approach

Sean J Jin, Sharon Y Kim iD, Jared Tallo, Harkaran S Rana, Sorana Raiciulescu, Morohunranti O Oguntoye-Ouma, Won I Kim

Journal of Clinical Medicine · 21.06.2025 · 14 (13) · 4426

DOI: 10.3390/jcm14134426 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 21.06.2025. Verfasst von Sean J Jin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, San Antonio Military Medical Center, San Antonio, TX 78234, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: This study evaluated the efficacy and safety of the ab externo open-conjunctiva (AEO) approach with adjunctive Ologen collagen matrix (OCM) compared to ab interno closed-conjunctiva (AIC) techniques for XEN45 gel stent implantation in patients with refractory open-angle glaucoma. The goal was to determine whether the AEO with OCM approach offers advantages in intraocular pressure (IOP) control and postoperative outcomes.

Methods

A retrospective, comparative case series was conducted on 76 eyes from 76 patients with open-angle glaucoma who underwent XEN45 implantation between 2017 and 2022 at a single tertiary center. The patients were divided into Group 1 (AEO with OCM, n = 47) and Group 2 (AIC, n = 29). Postoperative IOP, the number of glaucoma medications, surgical complications, bleb revisions, and failure rates were recorded over 12 months. The AEO technique, supported by OCM, was assessed for its potential to reduce postoperative fibrosis and improve long-term outcomes.

Results

Both groups experienced significant IOP reductions over time compared to baseline. However, Group 1 had superior outcomes, requiring fewer glaucoma medications postoperatively (p < 0.05), and demonstrated lower rates of complications (10.6% vs. 31.0%, p = 0.026) and bleb revisions (8.5% vs. 34.5%, p = 0.005). Kaplan–Meier survival analysis showed significantly greater cumulative surgical success in Group 1 compared to Group 2 (p < 0.001).

Conclusions

The AEO with OCM approach to XEN45 implantation may provide improved safety and efficacy compared to the AIC approach. It appears to be beneficial in minimizing postoperative fibrosis, reducing the medication burden, and lowering complication and failure rates. Prospective randomized trials are needed to validate these findings.

Schlagwörter

Stichwörter der Autor:innen

Minimally invasive glaucoma surgery (MIGS)Ologen collagen matrixXEN45 gel stentab externoab internoglaucoma surgery

Autor:innen und Institutionen

  • Department of Ophthalmology, San Antonio Military Medical Center, San Antonio, TX 78234, USA.
  • School of Medicine, Uniformed Services University, Bethesda, MD 20814, USA.
  • Department of Ophthalmology, Naval Medical Center San Diego, San Diego, CA 92134, USA.
  • Department of Ophthalmology, Walter Reed National Military Medical Center, Bethesda, MD 20814, USA.
  • Department of Preventive Medicine and Biostatistics, Uniformed Services University, Bethesda, MD 20814, USA.
  • Eye Doctors of Washington, Chevy Chase, MD 20815, USA.

ORCID-Profile: Sharon Y Kim

Zitieren

APA

Jin, S. J., Kim, S. Y., Tallo, J., Rana, H. S., Raiciulescu, S., Oguntoye-Ouma, M. O., & Kim, W. I. (2025). Comparison of XEN45 Gel Stent Outcomes in Glaucoma: Ab Externo Open-Conjunctiva Approach with Ologen vs. Ab Interno Closed-Conjunctiva Approach. Journal of Clinical Medicine, 14(13), 4426. https://doi.org/10.3390/jcm14134426

Vancouver

Jin SJ, Kim SY, Tallo J, Rana HS, Raiciulescu S, Oguntoye-Ouma MO, et al. Comparison of XEN45 Gel Stent Outcomes in Glaucoma: Ab Externo Open-Conjunctiva Approach with Ologen vs. Ab Interno Closed-Conjunctiva Approach. Journal of Clinical Medicine. 2025;14(13):4426. doi:10.3390/jcm14134426

BibTeX
@article{Jin2025,
  author = {Jin, Sean J and Kim, Sharon Y and Tallo, Jared and Rana, Harkaran S and Raiciulescu, Sorana and Oguntoye-Ouma, Morohunranti O and Kim, Won I},
  title = {Comparison of XEN45 Gel Stent Outcomes in Glaucoma: Ab Externo Open-Conjunctiva Approach with Ologen vs. Ab Interno Closed-Conjunctiva Approach},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {13},
  pages = {4426},
  doi = {10.3390/jcm14134426}
}
Kostenlos starten →