Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up

Yann Bertolani iD, Jaume Rigo-Quera, Laura Sánchez-Vela, Olivia Pujol-Carreras, Manuel Amilburu, Antonio Dou, Marta Castany iD

Journal of Clinical Medicine · 19.05.2025 · 14 (10) · 3545

DOI: 10.3390/jcm14103545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 19.05.2025. Verfasst von Yann Bertolani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Vall d'Hebron University Hospital, 08035 Barcelona, Spain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To compare the efficacy and safety of the XEN® 63 µm and 45 µm devices with the ab externo open conjunctiva with a 30G needle approach.

Methods

A retrospective, non-randomized and single-center study was conducted. Consecutive eyes undergoing a XEN® 63 µm implant were compared with a matched cohort of cases with a XEN® 45 µm implant. Standalone and combined procedures with phacoemulsification were included.

Results

A total of 28 XEN® 45 µm and 28 XEN® 63 µm were included. Complete surgical success was achieved in 17 cases (60.7%) in the 45 µm group and in 20 cases (71.4%) in the 63 µm group, with no statistical differences. One year after the surgery, the mean IOP was 13.8 ± 3.3 mmHg for the 45 µm group and 12.4 ± 4.2 mmHg for the 63 µm group (p-value > 0.05). Likewise, the use of glaucoma medication was lowered in the 63 µm device (0.32 ± 0.87) compared to the 45 µm device (0.39 ± 0.86), with no statistical significance. Postoperative hypotony was more frequent in the 63 µm device (39.3%) than in the 45 µm group (28.6%), with no statistical differences. However, hypotony-associated complications (including choroidal detachment, hypotony keratopathy, and hypotony maculopathy) were significantly higher in the 63 µm group (p = 0.011).

Conclusions

Although the XEN® 63 µm may offer a greater IOP-lowering effect with better complete surgical success, no significant differences were detected compared to the 45 µm device. Hypotony-related complications were higher in the XEN 63 µm, although most of them resolved with conservative management.

Schlagwörter

Stichwörter der Autor:innen

XEN® 45 µmXEN® 63 µmintraocular surgeryminimally invasive bleb surgeryminimally invasive glaucoma surgeryopen-conjunctiva approachsurvival analysis

Autor:innen und Institutionen

  • Department of Ophthalmology, Vall d'Hebron University Hospital, 08035 Barcelona, Spain.

ORCID-Profile: Yann Bertolani, Marta Castany

Zitieren

APA

Bertolani, Y., Rigo-Quera, J., Sánchez-Vela, L., Pujol-Carreras, O., Amilburu, M., Dou, A., & Castany, M. (2025). Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up. Journal of Clinical Medicine, 14(10), 3545. https://doi.org/10.3390/jcm14103545

Vancouver

Bertolani Y, Rigo-Quera J, Sánchez-Vela L, Pujol-Carreras O, Amilburu M, Dou A, et al. Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up. Journal of Clinical Medicine. 2025;14(10):3545. doi:10.3390/jcm14103545

BibTeX
@article{Bertolani2025,
  author = {Bertolani, Yann and Rigo-Quera, Jaume and Sánchez-Vela, Laura and Pujol-Carreras, Olivia and Amilburu, Manuel and Dou, Antonio and Castany, Marta},
  title = {Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {10},
  pages = {3545},
  doi = {10.3390/jcm14103545}
}
Kostenlos starten →