The Ascyrus Medical Dissection Stent: A One-Fits-All Strategy for the Treatment of Acute Type A Aortic Dissection?
Journal of Clinical Medicine · 28.04.2024 · 13 (9) · 2593
DOI: 10.3390/jcm13092593 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 28.04.2024. Verfasst von Leonard Pitts und 9 weiteren Autor:innen. Beteiligte Einrichtung: Deutsches Herzzentrum der Charité (DHZC), Department of Cardiothoracic and Vascular Surgery, Augustenburger Platz 1, 13353 Berlin, Germany. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The treatment of DeBakey type I aortic dissection remains a major challenge in the field of aortic surgery. To upgrade the standard of care hemiarch replacement, a novel device called an “Ascyrus Medical Dissection Stent” (AMDS) is now available. This hybrid device composed of a proximal polytetrafluoroethylene cuff and a distal non-covered nitinol stent is inserted into the aortic arch and the descending thoracic aorta during hypothermic circulatory arrest in addition to hemiarch replacement. Due to its specific design, it may result in a reduced risk for distal anastomotic new entries, the effective restoration of branch vessel malperfusion and positive aortic remodeling. In this narrative review, we provide an overview about the indications and the technical use of the AMDS. Additionally, we summarize the current available literature and discuss potential pitfalls in the application of the AMDS regarding device failure and aortic re-intervention.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Deutsches Herzzentrum der Charité (DHZC), Department of Cardiothoracic and Vascular Surgery, Augustenburger Platz 1, 13353 Berlin, Germany.
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany.
- Division of Cardiac Surgery, University of Alberta, Edmonton, AB T6G 1H9, Canada.
- Department of Cardiothoracic Surgery, Heart Centre, University of Cologne, 50923 Cologne, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, 10785 Berlin, Germany.
- Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH), 8092 Zurich, Switzerland.
ORCID-Profile: Leonard Pitts, Maximilian Luehr, Markus Kofler, Semih Buz
Zitieren
APA
Pitts, L., Moon, M. C., Luehr, M., Kofler, M., Montagner, M., Sündermann, S., Buz, S., Starck, C., Falk, V., & Kempfert, J. (2024). The Ascyrus Medical Dissection Stent: A One-Fits-All Strategy for the Treatment of Acute Type A Aortic Dissection?. Journal of Clinical Medicine, 13(9), 2593. https://doi.org/10.3390/jcm13092593
Vancouver
Pitts L, Moon MC, Luehr M, Kofler M, Montagner M, Sündermann S, et al. The Ascyrus Medical Dissection Stent: A One-Fits-All Strategy for the Treatment of Acute Type A Aortic Dissection?. Journal of Clinical Medicine. 2024;13(9):2593. doi:10.3390/jcm13092593
BibTeX
@article{Pitts2024,
author = {Pitts, Leonard and Moon, Michael C and Luehr, Maximilian and Kofler, Markus and Montagner, Matteo and Sündermann, Simon and Buz, Semih and Starck, Christoph and Falk, Volkmar and Kempfert, Jörg},
title = {The Ascyrus Medical Dissection Stent: A One-Fits-All Strategy for the Treatment of Acute Type A Aortic Dissection?},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {9},
pages = {2593},
doi = {10.3390/jcm13092593}
}
EUVIMED