Treatment of acute type A aortic dissection with the Ascyrus Medical Dissection Stent in a consecutive series of 57 cases
European Journal of Cardio-Thoracic Surgery · 01.03.2023 · 63 (3)
DOI: 10.1093/ejcts/ezac581 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 22.12.2022. Verfasst von Maximilian Luehr und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Heart Centre, University of Cologne, Cologne, Germany. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Aortic Dissection, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES The Ascyrus Medical Dissection Stent (AMDS) has been recently introduced as an alternative for total arch replacement in acute aortic dissection type A (AADA). The aim of this study was to evaluate the postoperative outcomes after AMDS treatment in a large contemporary cohort of AADA patients. METHODS Data acquisition was performed retrospectively at 2 German aortic centres between 2020 and 2022 and comprised the perioperative parameters and postoperative results of all AADA patients. All patients treated with the AMDS for AADA were included in the study. The primary end point was in-hospital mortality. Secondary end points were defined as early postoperative and AMDS-related complications. RESULTS Fifty-seven AADA patients treated by AMDS were included in the study group. The mean age was 64.6 ± 10.8 years and 59.7% (n = 34) were males. The actual in-hospital mortality was considerably lower than the predicted mortality risk by the German registry for acute aortic dissection type A score (16% vs 22%). The median ICU and in-hospital stay were 5 (interquartile range: 3–13) and 12 (interquartile range: 10–22) days, respectively. Postoperative complications comprised acute renal insufficiency (37%) with need for temporary (16%) or permanent dialysis (5%), delirium (26%), re-exploration for bleeding (14%), tracheostomy (14%) and new stroke (4%). A new AMDS-related complication (central stent collapse) was observed in 9% (n = 5) by postoperative computed tomography and chest X-ray. The incidence of complete central AMDS collapse did not impact 30-day mortality. CONCLUSIONS The AMDS may be successfully used in AADA with acceptable 30-day mortality in accordance with the German registry for acute aortic dissection type A score. However, careful preoperative evaluation of the patient’s individual aortic anatomy regarding potential contraindications and proper device implantation are strongly recommended to avoid complete central AMDS collapse.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, Heart Centre, University of Cologne, Cologne, Germany.
- Department of Cardiovascular Surgery, Goethe University and University Hospital Frankfurt, Frankfurt, Germany.
ORCID-Profile: Maximilian Luehr, Christopher Gaisendrees, Georg Schlachtenberger, Thomas Walther, Tomas Holubec
Zitieren
APA
Luehr, M., Gaisendrees, C., Yilmaz, A. K., Winderl, L., Schlachtenberger, G., Van Linden, A., Wahlers, T., Walther, T., & Holubec, T. (2023). Treatment of acute type A aortic dissection with the Ascyrus Medical Dissection Stent in a consecutive series of 57 cases. European Journal of Cardio-Thoracic Surgery, 63(3). https://doi.org/10.1093/ejcts/ezac581
Vancouver
Luehr M, Gaisendrees C, Yilmaz AK, Winderl L, Schlachtenberger G, Van Linden A, et al. Treatment of acute type A aortic dissection with the Ascyrus Medical Dissection Stent in a consecutive series of 57 cases. European Journal of Cardio-Thoracic Surgery. 2023;63(3). doi:10.1093/ejcts/ezac581
BibTeX
@article{Luehr2023,
author = {Luehr, Maximilian and Gaisendrees, Christopher and Yilmaz, Abdul Kadir and Winderl, Leila and Schlachtenberger, Georg and Van Linden, Arnaud and Wahlers, Thorsten and Walther, Thomas and Holubec, Tomas},
title = {Treatment of acute type A aortic dissection with the Ascyrus Medical Dissection Stent in a consecutive series of 57 cases},
journal = {European Journal of Cardio-Thoracic Surgery},
year = {2023},
volume = {63},
number = {3},
doi = {10.1093/ejcts/ezac581}
}
EUVIMED