EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

DiabeticSense: A Non-Invasive, Multi-Sensor, IoT-Based Pre-Diagnostic System for Diabetes Detection Using Breath

Ritu Kapur iD, Yashwant Kumar, Swati Sharma, Vedant Rastogi, Shivani Sharma, Vikrant Kanwar, Tarun Sharma, Arnav Bhavsar iD, Varun Dutt iD

Journal of Clinical Medicine · 10.10.2023 · 12 (20) · 6439

DOI: 10.3390/jcm12206439 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 10.10.2023. Verfasst von Ritu Kapur und 8 weiteren Autor:innen. Beteiligte Einrichtung: Indian Knowledge System and Mental Health Applications Centre, Indian Institute of Technology Mandi, Kamand 175075, Himachal Pradesh, India. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: IIT Mandi iHub/ HCIF, IIT Mandi iHub and Human-Computer Interaction (HCI) Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diabetes mellitus is a widespread chronic metabolic disorder that requires regular blood glucose level surveillance. Current invasive techniques, such as finger-prick tests, often result in discomfort, leading to infrequent monitoring and potential health complications. The primary objective of this study was to design a novel, portable, non-invasive system for diabetes detection using breath samples, named DiabeticSense, an affordable digital health device for early detection, to encourage immediate intervention. The device employed electrochemical sensors to assess volatile organic compounds in breath samples, whose concentrations differed between diabetic and non-diabetic individuals. The system merged vital signs with sensor voltages obtained by processing breath sample data to predict diabetic conditions. Our research used clinical breath samples from 100 patients at a nationally recognized hospital to form the dataset. Data were then processed using a gradient boosting classifier model, and the performance was cross-validated. The proposed system attained a promising accuracy of 86.6%, indicating an improvement of 20.72% over an existing regression technique. The developed device introduces a non-invasive, cost-effective, and user-friendly solution for preliminary diabetes detection. This has the potential to increase patient adherence to regular monitoring.

Schlagwörter

Stichwörter der Autor:innen

bio-markersblood glucose monitoringdiabetesdiabetes testdigital health devicesexhaled breath analysisnon-invasivevolatile organic compounds

Autor:innen und Institutionen

  • Indian Knowledge System and Mental Health Applications Centre, Indian Institute of Technology Mandi, Kamand 175075, Himachal Pradesh, India.
  • All India Institute of Medical Science Bilaspur, Noa 174001, Himachal Pradesh, India.

ORCID-Profile: Ritu Kapur, Arnav Bhavsar, Varun Dutt

Förderung

  • IIT Mandi iHub/ HCIF
  • IIT Mandi iHub and Human-Computer Interaction (HCI) Foundation

Zitieren

APA

Kapur, R., Kumar, Y., Sharma, S., Rastogi, V., Sharma, S., Kanwar, V., Sharma, T., Bhavsar, A., & Dutt, V. (2023). DiabeticSense: A Non-Invasive, Multi-Sensor, IoT-Based Pre-Diagnostic System for Diabetes Detection Using Breath. Journal of Clinical Medicine, 12(20), 6439. https://doi.org/10.3390/jcm12206439

Vancouver

Kapur R, Kumar Y, Sharma S, Rastogi V, Sharma S, Kanwar V, et al. DiabeticSense: A Non-Invasive, Multi-Sensor, IoT-Based Pre-Diagnostic System for Diabetes Detection Using Breath. Journal of Clinical Medicine. 2023;12(20):6439. doi:10.3390/jcm12206439

BibTeX
@article{Kapur2023,
  author = {Kapur, Ritu and Kumar, Yashwant and Sharma, Swati and Rastogi, Vedant and Sharma, Shivani and Kanwar, Vikrant and Sharma, Tarun and Bhavsar, Arnav and Dutt, Varun},
  title = {DiabeticSense: A Non-Invasive, Multi-Sensor, IoT-Based Pre-Diagnostic System for Diabetes Detection Using Breath},
  journal = {Journal of Clinical Medicine},
  year = {2023},
  volume = {12},
  number = {20},
  pages = {6439},
  doi = {10.3390/jcm12206439}
}
Kostenlos starten →