Comparison of Virtual Intersection and Occlusal Contacts between Intraoral and Laboratory Scans: An In-Vivo Study

Florian Beck iD, Stefan Lettner iD, Lana Zupancic Cepic iD, Andreas Schedle

Journal of Clinical Medicine · 28.01.2023 · 12 (3) · 996

DOI: 10.3390/jcm12030996 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 28.01.2023. Verfasst von Florian Beck und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute Straumann AG.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background. The inaccurate maxillomandibular relationship of virtual casts following alignment by the vestibular scan may result in intersection (intermesh penetration) between opposing dental arch surfaces. Intersection occurs at short interocclusal distances in the occlusal contact area (OCA) and may result in infra-occluded definitive restorations. The purpose of this clinical study was to compare initial (by the proprietary scanner software) and new alignments (by a standalone 3D software) of virtual casts regarding OCA and intersection failure. New alignments aimed to rectify intersections by refinement of occlusal contacts. Material and Methods. The virtual casts of 30 patients following digital and conventional impression-taking were analyzed, which were acquired for single implant restoration in the posterior site. Digital impressions were performed by both IOS 1 (3M True Definition) and IOS 2 (TRIOS 3), either as complete- or partial-arch scans, respectively. Mounted gypsum casts were digitized as complete-arch by a laboratory scanner (LS) in enabled and disabled mode to avoid intersection [LS (+)/LS (−)]. All virtual casts were newly aligned by a 3D software. The difference of the OCA and the area of intersection were calculated for initial and new alignments, using interocclusal distance ranges of 0–100 μm, 0–10 μm or

Schlagwörter

Stichwörter der Autor:innen

CAD/CAMalignmentdigital impressionintermesh penetrationintersectionintraoral scanningocclusionvirtual castvirtual occlusal record

Autor:innen und Institutionen

  • Division of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria.
  • Core Facility Hard Tissue Research and Biomaterial Research, Karl Donath Laboratory, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria.
  • Division of Prosthodontics, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria.
  • Competence Center Dental Materials, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria.

ORCID-Profile: Florian Beck, Stefan Lettner, Lana Zupancic Cepic

Förderung

  • Institute Straumann AG

Zitieren

APA

Beck, F., Lettner, S., Zupancic Cepic, L., & Schedle, A. (2023). Comparison of Virtual Intersection and Occlusal Contacts between Intraoral and Laboratory Scans: An In-Vivo Study. Journal of Clinical Medicine, 12(3), 996. https://doi.org/10.3390/jcm12030996

Vancouver

Beck F, Lettner S, Zupancic Cepic L, Schedle A. Comparison of Virtual Intersection and Occlusal Contacts between Intraoral and Laboratory Scans: An In-Vivo Study. Journal of Clinical Medicine. 2023;12(3):996. doi:10.3390/jcm12030996

BibTeX
@article{Beck2023,
  author = {Beck, Florian and Lettner, Stefan and Zupancic Cepic, Lana and Schedle, Andreas},
  title = {Comparison of Virtual Intersection and Occlusal Contacts between Intraoral and Laboratory Scans: An In-Vivo Study},
  journal = {Journal of Clinical Medicine},
  year = {2023},
  volume = {12},
  number = {3},
  pages = {996},
  doi = {10.3390/jcm12030996}
}
Kostenlos starten →