EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Early Echocardiographic Changes Following Transcatheter Aortic Valve Implantation: A Comparative Analysis of Different Transcatheter Aortic Valve Systems

Huseyin Dursun, Tugce Colluoglu iD, Bihter Senturk iD, Hatice Ozdamar, Cisem Oktay iD, Hacer Uysal, Husna Tugce Simsek, Zulkif Tanriverdi iD, Dayimi Kaya iD

Journal of Cardiovascular Development and Disease · 22.04.2026 · 13 (5) · 173

DOI: 10.3390/jcdd13050173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 22.04.2026. Verfasst von Huseyin Dursun und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Faculty of Medicine, Dokuz Eylül University, Izmir 35340, Turkey. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter aortic valve implantation (TAVI) is a viable alternative therapeutic approach for patients with severe aortic stenosis (AS), following technological innovations in transcatheter aortic valve systems and advances in clinical expertise, which aim to optimize valve hemodynamics. In this study, we aimed to compare early hemodynamic changes in different types of TAVI valves via two-dimensional echocardiography.

Methods

This retrospective observational study examined patients with severe AS who underwent transfemoral TAVI. Patients were classified according to expansion mechanism (self-expanding valves (SEVs) or balloon-expandable valves (BEVs)) and leaflet position relative to the annulus (supra-annular valves (SAVs) or intra-annular valves (IAVs)). The implanted prostheses were Edwards SAPIEN XT valves (ESV, Edwards Lifesciences, Irvine, CA, USA), Medtronic valves (Core Valve-MCV and Evolut R, Medtronic, Minneapolis, MN, USA), Portico valves (St. Jude Medical, Saint Paul, MN, USA), and Myval valves (Meril Life Sciences, Vapi, India). Baseline two-dimensional transthoracic echocardiography (TTE) datasets were compared with post-TAVI measures obtained before discharge.

Results

In total (n = 332), 275 (82.8%) patients were treated with SEVs, and 57 (17.2%) were treated with BEVs. In terms of leaflet position, 249 (75%) patients were treated with SAVs, and the remaining 83 (25%) patients were treated with IAVs. Transaortic gradients were comparable between patients treated with SEVs and BEVs. However, patients treated with IAVs exhibited significantly higher aortic maximum gradients (16 [13–21] mmHg vs. 14 [10–20] mmHg, p = 0.019) and mean gradients (9 [7–11] mmHg vs. 8 [5–10] mmHg, p = 0.014) compared to those receiving SAVs. Post-TAVI gradients were also compared based on each TAVI device. Although post-TAVI aortic maximum gradient was comparable among TAVI devices (p = 0.080), aortic mean gradient was significantly different among the valves (p = 0.006). Post hoc analyses demonstrated that the post-TAVI mean gradient was significantly lower in Medtronic CoreValve compared to the Myval (p = 0.013) and Portico (p = 0.030). No significant differences were observed in the frequency of perivalvular leak between the valve groups.

Conclusions

We found that post-TAVI transaortic gradients of SEVs and BEVs were comparable; however, SAVs were associated with lower transaortic gradients than those of the IAVs. In addition, the frequency of ≥moderate PVL was comparable between the valve groups.

Schlagwörter

Stichwörter der Autor:innen

TAVI valvestranscatheter aortic valve implantationtwo-dimensional echocardiographyvalve hemodynamics

Autor:innen und Institutionen

  • Department of Cardiology, Faculty of Medicine, Dokuz Eylül University, Izmir 35340, Turkey.
  • Department of Cardiology, Tepecik Training and Research Hospital, Izmir 35020, Turkey.
  • Department of Cardiology, Faculty of Medicine, Harran University, Sanliurfa 63300, Turkey.

ORCID-Profile: Tugce Colluoglu, Bihter Senturk, Cisem Oktay, Zulkif Tanriverdi, Dayimi Kaya

Zitieren

APA

Dursun, H., Colluoglu, T., Senturk, B., Ozdamar, H., Oktay, C., Uysal, H., Simsek, H. T., Tanriverdi, Z., & Kaya, D. (2026). Early Echocardiographic Changes Following Transcatheter Aortic Valve Implantation: A Comparative Analysis of Different Transcatheter Aortic Valve Systems. Journal of Cardiovascular Development and Disease, 13(5), 173. https://doi.org/10.3390/jcdd13050173

Vancouver

Dursun H, Colluoglu T, Senturk B, Ozdamar H, Oktay C, Uysal H, et al. Early Echocardiographic Changes Following Transcatheter Aortic Valve Implantation: A Comparative Analysis of Different Transcatheter Aortic Valve Systems. Journal of Cardiovascular Development and Disease. 2026;13(5):173. doi:10.3390/jcdd13050173

BibTeX
@article{Dursun2026,
  author = {Dursun, Huseyin and Colluoglu, Tugce and Senturk, Bihter and Ozdamar, Hatice and Oktay, Cisem and Uysal, Hacer and Simsek, Husna Tugce and Tanriverdi, Zulkif and Kaya, Dayimi},
  title = {Early Echocardiographic Changes Following Transcatheter Aortic Valve Implantation: A Comparative Analysis of Different Transcatheter Aortic Valve Systems},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2026},
  volume = {13},
  number = {5},
  pages = {173},
  doi = {10.3390/jcdd13050173}
}
Kostenlos starten →