EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing

Sarah Bashour, Bassam Hwaija, Fadwa Issa, Firas Al Mahmoud, George Wardeh

Infrastructures · 13.07.2026 · 11 (7) · 236

DOI: 10.3390/infrastructures11070236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infrastructures, online erschienen am 13.07.2026. Verfasst von Sarah Bashour und 4 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Coupled shear wall systems are widely used in tall buildings due to their high lateral stiffness and effectiveness in controlling wind-induced serviceability responses. Reliable assessment of their behavior under realistic wind loading requires accurate load representation and properly calibrated numerical modeling. This study investigates the performance of coupled shear wall systems under wind loads derived from wind tunnel testing, where surface pressure time histories were extracted from the TPU Aerodynamic Database and used to generate equivalent full-scale, time-varying wind loads. The preliminary design of a 20-story building was established in ETABS based on current design codes. Detailed nonlinear time-history analyses were subsequently performed in OpenSees to assess the performance under three different wind hazards for the original and refined design, where shear walls were modeled using the Multiple-Vertical-Line-Element Model (MVLEM). Several wind demand indicators, including drift ratios, floor accelerations, and component and cladding performance were evaluated. The results demonstrate that the performance-based design framework enables the identification of critical vulnerabilities that may not be fully captured by conventional code-based drift and strength checks, particularly regarding localized damage accumulation and serviceability-related demands. Additionally, the refined configuration, while requiring only a 4.33% increase in total baseline concrete volume, effectively reduced peak roof drift by 60%, allowing reliable control of dynamic behavior and prevention of structural yielding, as well as ensuring the maintenance of both structural integrity and operational serviceability for the investigated high-rise configuration during severe wind events. Nevertheless, the findings are limited to the investigated building configuration and aerodynamic conditions considered in this study.

Zitieren

APA

Bashour, S., Hwaija, B., Issa, F., Mahmoud, F. A., & Wardeh, G. (2026). Wind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing. Infrastructures, 11(7), 236. https://doi.org/10.3390/infrastructures11070236

Vancouver

Bashour S, Hwaija B, Issa F, Mahmoud FA, Wardeh G. Wind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing. Infrastructures. 2026;11(7):236. doi:10.3390/infrastructures11070236

BibTeX
@article{Bashour2026,
  author = {Bashour, Sarah and Hwaija, Bassam and Issa, Fadwa and Mahmoud, Firas Al and Wardeh, George},
  title = {Wind-Induced Response of Coupled Shear Wall Systems Based on Wind Tunnel Testing},
  journal = {Infrastructures},
  year = {2026},
  volume = {11},
  number = {7},
  pages = {236},
  doi = {10.3390/infrastructures11070236}
}