Evaluation of the Timed Up and Go Test in Patients with Knee Osteoarthritis Using Inertial Sensors
International Journal of Translational Medicine · 25.12.2024 · 5 (1) · 2
DOI: 10.3390/ijtm5010002 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Translational Medicine, online erschienen am 25.12.2024. Verfasst von Elina Gianzina und 4 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
There has been a growing interest in using inertial sensors to explore the temporal aspects of the Timed Up and Go (TUG) test. The current study aimed to analyze the spatiotemporal parameters and phases of the TUG test in patients with knee osteoarthritis (KOA) and compare the results with those of non-arthritic individuals.
Methods
This study included 20 patients with KOA and 60 non-arthritic individuals aged 65 to 84 years. All participants performed the TUG test, and 17 spatiotemporal parameters and phase data were collected wirelessly using the BTS G-Walk inertial sensor.
Results
Significant mobility impairments were observed in KOA patients, including slower gait speed, impaired sit-to-stand transitions, and reduced turning efficiency. These findings highlight functional deficits in individuals with KOA compared to their non-arthritic counterparts.
Conclusions
The results emphasize the need for targeted physiotherapy interventions, such as quadriceps strengthening, balance training, and gait retraining, to address these deficits. However, the study is limited by its small sample size, gender imbalance, and limited validation of the BTS G-Walk device. Future research should include larger, more balanced cohorts, validate sensor reliability, and conduct longitudinal studies. Despite these limitations, the findings align with previous research and underscore the potential of inertial sensors in tailoring rehabilitation strategies and monitoring progress in KOA patients.
Zitieren
APA
Gianzina, E., Yiannakopoulos, C., Kalinterakis, G., Delis, S., & Chronopoulos, E. (2024). Evaluation of the Timed Up and Go Test in Patients with Knee Osteoarthritis Using Inertial Sensors. International Journal of Translational Medicine, 5(1), 2. https://doi.org/10.3390/ijtm5010002
Vancouver
Gianzina E, Yiannakopoulos C, Kalinterakis G, Delis S, Chronopoulos E. Evaluation of the Timed Up and Go Test in Patients with Knee Osteoarthritis Using Inertial Sensors. International Journal of Translational Medicine. 2024;5(1):2. doi:10.3390/ijtm5010002
BibTeX
@article{Gianzina2024,
author = {Gianzina, Elina and Yiannakopoulos, Christos and Kalinterakis, Georgios and Delis, Spilios and Chronopoulos, Efstathios},
title = {Evaluation of the Timed Up and Go Test in Patients with Knee Osteoarthritis Using Inertial Sensors},
journal = {International Journal of Translational Medicine},
year = {2024},
volume = {5},
number = {1},
pages = {2},
doi = {10.3390/ijtm5010002}
}
EUVIMED