Instrumented Functional Mobility Assessment in Elderly Patients Following Total Knee Arthroplasty: A Retrospective Longitudinal Study Using the Timed Up and Go Test
Life · 07.09.2025 · 15 (9) · 1409
DOI: 10.3390/life15091409 ↗Kurz gefasst
Fachartikel in der Zeitschrift Life, online erschienen am 07.09.2025. Verfasst von Andrei Machado Viegas da Trindade und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics Surgery, Municipal Hospital of Aparecida de Goiânia (HMAP), Aparecida de Goiânia 74936-600, Brazil. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Mobilisation
Abstract (Originalsprache)
In the context of the rising demand for total knee arthroplasty (TKA) in older adults and persistent uncertainty about the quality of long-term functional recovery, this study evaluated elderly patients’ mobility after unilateral TKA via a transquadriceps approach using instrumented Timed Up and Go (TUG) tests. A total of 20 patients treated between 2022 and 2024 at a tertiary hospital were invited to participate in this observational, retrospective, descriptive study, and 19 met the inclusion criteria (age 50–80 and Kellgren–Lawrence ≥ 4). The participants performed two TUG trials at two postoperative time points (18 and 53 months), with an inertial measurement unit (G-sensor) capturing 15 kinematic variables. When comparing the postoperative time points, it was found that the total TUG duration remained stable (14.97 ± 3.48 vs. 15.47 ± 2.93 s; p = 0.58), while the mid-turning peak velocity increased significantly (106.44 ± 30.96 vs. 132.77 ± 30.82°/s; p = 0.0039; r = 0.88). The end-turning velocity and sit-to-stand parameters showed small-to-moderate effect size gains without statistical significance. These findings suggest that, in the first year following surgery, patients continue to experience difficulties with movement fluidity and motor control—especially during turning—underscoring the value of segmented, sensor-based assessments and the need for extended rehabilitation protocols that emphasize rotational control and balance. These findings provide clinically relevant parameters that can support future interventional studies and help guide rehabilitation planning after TKA.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics Surgery, Municipal Hospital of Aparecida de Goiânia (HMAP), Aparecida de Goiânia 74936-600, Brazil.
- Health Sciences Program, Santa Casa de São Paulo School of Medical Sciences, São Paulo 01221-020, Brazil.
- Faculty of Medicine, University Evangelica of Goiás, Anápolis 75083-515, Brazil.
- Department of Orthopaedics and Traumatology, Federal University of Goiás (UFG), Goiânia 74605-050, Brazil.
- Human Movement Analysis Laboratory, University Evangelica of Goiás, Anápolis 75083-515, Brazil.
ORCID-Profile: Leonardo Pinheiro Rezende, Rodolfo Borges Parreira
Zitieren
APA
Trindade, A. M. V. D., Rezende, L. P., Araújo, H. R. D. S., Parreira, R. B., & Oliveira, C. S. (2025). Instrumented Functional Mobility Assessment in Elderly Patients Following Total Knee Arthroplasty: A Retrospective Longitudinal Study Using the Timed Up and Go Test. Life, 15(9), 1409. https://doi.org/10.3390/life15091409
Vancouver
Trindade AMVD, Rezende LP, Araújo HRDS, Parreira RB, Oliveira CS. Instrumented Functional Mobility Assessment in Elderly Patients Following Total Knee Arthroplasty: A Retrospective Longitudinal Study Using the Timed Up and Go Test. Life. 2025;15(9):1409. doi:10.3390/life15091409
BibTeX
@article{Trindade2025,
author = {Trindade, Andrei Machado Viegas da and Rezende, Leonardo Pinheiro and Araújo, Helder Rocha da Silva and Parreira, Rodolfo Borges and Oliveira, Claudia Santos},
title = {Instrumented Functional Mobility Assessment in Elderly Patients Following Total Knee Arthroplasty: A Retrospective Longitudinal Study Using the Timed Up and Go Test},
journal = {Life},
year = {2025},
volume = {15},
number = {9},
pages = {1409},
doi = {10.3390/life15091409}
}