A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification
International Journal of Molecular Sciences · 2024
DOI: 10.3390/ijms25189771 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2024. Verfasst von Ruodong Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Department of Biomedical Engineering, Jinan University, Guangzhou 5106https:…. Hauptthemen laut MEDLINE: C-Reactive Protein, Nanoparticles, Polymers. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Science and Technology Program of Guangzhou.
Abstract (Originalsprache)
The low-cost daily monitoring of C-reactive protein (CRP) levels is crucial for screening acute inflammation or infections as well as managing chronic inflammatory diseases. In this study, we synthesized novel 2-Methacryloyloxy ethyl phosphorylcholine (MPC)-based biomimetic nanoparticles with a large surface area to develop a visual CRP-quantification assay using affordable glass capillaries. The PMPC nanoparticles, synthesized via reflux precipitation polymerization, demonstrated multivalent binding capabilities, enabling rapid and specific CRP capture. In the presence of CRP, PMPC nanoparticles formed sandwich structures with magnetic nanoparticles functionalized with CRP antibodies, thereby enhancing detection sensitivity and specificity. These sandwich complexes were magnetically accumulated into visible and quantifiable stacks within the glass capillaries, allowing for the rapid, sensitive, and specific quantification of CRP concentrations with a detection limit of 57.5 pg/mL and a range spanning from 0 to 5000 ng/mL. The proposed visual distance-based capillary biosensor shows great potential in routine clinical diagnosis as well as point-of-care testing (POCT) in resource-limited settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Department of Biomedical Engineering, Jinan University, Guangzhou 5106https://susy.mdpi.com/manuscript/publishing/publish/5920461659f317d0555d60b6…
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Guangdong Province
- Science and Technology Program of Guangzhou
- the Fundamental Research Funds for the Central Universities
Zitieren
APA
Huang, R., Liu, Z., Jiang, X., Huang, J., Zhou, P., Mou, Z., Ma, D., & Cui, X. (2024). A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms25189771
Vancouver
Huang R, Liu Z, Jiang X, Huang J, Zhou P, Mou Z, et al. A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification. International Journal of Molecular Sciences. 2024. doi:10.3390/ijms25189771
BibTeX
@article{Huang2024,
author = {Huang, Ruodong and Liu, Zhenbo and Jiang, Xinlin and Huang, Junqi and Zhou, Ping and Mou, Zongxia and Ma, Dong and Cui, Xin},
title = {A Visual Distance-Based Capillary Immunoassay Using Biomimetic Polymer Nanoparticles for Highly Sensitive and Specific C-Reactive Protein Quantification},
journal = {International Journal of Molecular Sciences},
year = {2024},
doi = {10.3390/ijms25189771}
}
EUVIMED