EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Surface Contaminants and Hydrocarbon Pellicle on the Results of Wettability Measurements of Titanium

Daisuke Kido, Keiji Komatsu iD, Toshikatsu Suzumura, Takanori Matsuura iD, James Cheng, Jeong Kim, Wonhee Park iD, Takahiro Ogawa

International Journal of Molecular Sciences · 28.09.2023 · 24 (19) · 14688

DOI: 10.3390/ijms241914688 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Molecular Sciences, online erschienen am 28.09.2023. Verfasst von Daisuke Kido und 7 weiteren Autor:innen. Beteiligte Einrichtung: Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90…. Hauptthemen laut MEDLINE: Titanium, Dental Implants. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DIO IMPLANT Co., Ltd..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydrophilicity/hydrophobicity—or wettability—is a key surface characterization metric for titanium used in dental and orthopedic implants. However, the effects of hydrophilicity/hydrophobicity on biological capability remain uncertain, and the relationships between surface wettability and other surface parameters, such as topography and chemistry, are poorly understood. The objective of this study was to identify determinants of surface wettability of titanium and establish the reliability and validity of the assessment. Wettability was evaluated as the contact angle of ddH2O. The age of titanium specimens significantly affected the contact angle, with acid-etched, microrough titanium surfaces becoming superhydrophilic immediately after surface processing, hydrophobic after 7 days, and hydrorepellent after 90 days. Similar age-related loss of hydrophilicity was also confirmed on sandblasted supra-micron rough surfaces so, regardless of surface topography, titanium surfaces eventually become hydrophobic or hydrorepellent with time. On age-standardized titanium, surface roughness increased the contact angle and hydrophobicity. UV treatment of titanium regenerated the superhydrophilicity regardless of age or surface roughness, with rougher surfaces becoming more superhydrophilic than machined surfaces after UV treatment. Conditioning titanium surfaces by autoclaving increased the hydrophobicity of already-hydrophobic surfaces, whereas conditioning with 70% alcohol and hydrating with water or saline attenuated pre-existing hydrophobicity. Conversely, when titanium surfaces were superhydrophilic like UV-treated ones, autoclaving and alcohol cleaning turned the surfaces hydrorepellent and hydrophobic, respectively. UV treatment recovered hydrophilicity without exception. In conclusion, surface roughness accentuates existing wettability and can either increase or decrease the contact angle. Titanium must be age-standardized when evaluating surface wettability. Surface conditioning techniques significantly but unpredictably affect existing wettability. These implied that titanium wettability is significantly influenced by the hydrocarbon pellicle and other contaminants inevitably accumulated. UV treatment may be an effective strategy to standardize wettability by making all titanium surfaces superhydrophilic, thereby allowing the characterization of individual surface topography and chemistry parameters in future studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumDental ImplantsWettabilitySurface PropertiesReproducibility of ResultsHydrophobic and Hydrophilic InteractionsMicroscopy, Electron, Scanning

Stichwörter der Autor:innen

UV photofunctionalizationbone integrationosseointegrationtitanium implantswettability

Substanzen

TitaniumDental Implants

Autor:innen und Institutionen

  • Weintraub Center for Reconstructive Biotechnology, Division of Regenerative and Reconstructive Sciences, UCLA School of Dentistry, Los Angeles, CA 90095-1668, USA.
  • Department of Oral Diagnosis and General Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.

ORCID-Profile: Keiji Komatsu, Takanori Matsuura, Wonhee Park

Förderung

  • DIO IMPLANT Co., Ltd.

Zitieren

APA

Kido, D., Komatsu, K., Suzumura, T., Matsuura, T., Cheng, J., Kim, J., Park, W., & Ogawa, T. (2023). Influence of Surface Contaminants and Hydrocarbon Pellicle on the Results of Wettability Measurements of Titanium. International Journal of Molecular Sciences, 24(19), 14688. https://doi.org/10.3390/ijms241914688

Vancouver

Kido D, Komatsu K, Suzumura T, Matsuura T, Cheng J, Kim J, et al. Influence of Surface Contaminants and Hydrocarbon Pellicle on the Results of Wettability Measurements of Titanium. International Journal of Molecular Sciences. 2023;24(19):14688. doi:10.3390/ijms241914688

BibTeX
@article{Kido2023,
  author = {Kido, Daisuke and Komatsu, Keiji and Suzumura, Toshikatsu and Matsuura, Takanori and Cheng, James and Kim, Jeong and Park, Wonhee and Ogawa, Takahiro},
  title = {Influence of Surface Contaminants and Hydrocarbon Pellicle on the Results of Wettability Measurements of Titanium},
  journal = {International Journal of Molecular Sciences},
  year = {2023},
  volume = {24},
  number = {19},
  pages = {14688},
  doi = {10.3390/ijms241914688}
}
Kostenlos starten →