EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Microporous zirconium-coated titanium surfaces for dental implant application: Surface characterization, bioactivity and effect on the oral biofilm formation

Yumi C Del Rey, Rubens F Albuquerque-Junior, Ana Paula Ramos, Bárbara Araújo Dos Reis, Leandro Fernandes, Luis G Vaz, Cássio do Nascimento

Journal of Materials Science: Materials in Medicine · 2025

DOI: 10.1007/s10856-025-06985-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Materials Science: Materials in Medicine, 2025. Verfasst von Yumi C Del Rey und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, São Paulo University (USP), Ribeirão Preto, SP, Brazil. Hauptthemen laut MEDLINE: Titanium, Biofilms, Zirconium, Dental Implants. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implantable materials based on titanium have been widely used in medical and dental care due to favorable mechanical properties and biocompatibility. However, when compared to ceramics, titanium surfaces are more susceptible to bacterial adhesion and colonization by periodontopathogenic species. Peri-implant infections are the major cause of implant failure and development of implantable materials with surface properties effective in minimizing bacterial colonization is still a challenge. Plasma electrolytic oxidation (PEO) provides porous ceramic coatings of high durability and stability on titanium. Incorporating metals with antimicrobial effects may contribute to minimizing microorganism adhesion on titanium. This study developed a novel zirconium-coated titanium surface using PEO and compared the composition of oral biofilm with machined or double acid etched surfaces in situ. SEM analysis showed pores and micro-pores, respectively for PEO and zirconium coatings, with surface roughness lower than acid etching while maintaining moderate levels (Ra/Sa: 1.0-2.0 µm). Chemical composition analysis showed predomination of TiO 2 on the most superficial layer of all groups with phosphorous and calcium incorporated into PEO coatings; calcium was replaced by a relevant amount of zirconium after anodization. Both PEO and zirconium coatings presented reduced values of surface free energy and less wettability than control and etched surfaces. DNA Checkerboard hybridization analysis showed that zirconium coatings significantly reduced the total microbial counts on the formed biofilms with lower counts of opportunistic and pathogenic species. In conclusion, PEO and zirconium coatings have substantially modified the microbial colonization pattern of biofilms, with preferential colonization by commensal Streptococci on zirconium surfaces. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumBiofilmsZirconiumDental ImplantsCoated Materials, BiocompatibleSurface PropertiesMaterials TestingBacterial AdhesionPorosityHumansMicroscopy, Electron, ScanningWettability

Substanzen

TitaniumZirconiumDental ImplantsCoated Materials, Biocompatible

Autor:innen und Institutionen

  • Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, São Paulo University (USP), Ribeirão Preto, SP, Brazil.
  • Department of Chemistry, Ribeirão Preto College of Philosophy Sciences and Letters, São Paulo University (USP), Ribeirão Preto, SP, Brazil.
  • Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University (UNESP), Araraquara, SP, Brazil.
  • Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, São Paulo University (USP), Ribeirão Preto, SP, Brazil. cassionasc@forp.usp.br.

Zitieren

APA

Del Rey, Y. C., Albuquerque-Junior, R. F., Ramos, A. P., Dos Reis, B. A., Fernandes, L., Vaz, L. G., & do Nascimento, C. (2025). Microporous zirconium-coated titanium surfaces for dental implant application: Surface characterization, bioactivity and effect on the oral biofilm formation. Journal of Materials Science: Materials in Medicine. https://doi.org/10.1007/s10856-025-06985-1

Vancouver

Del Rey YC, Albuquerque-Junior RF, Ramos AP, Dos Reis BA, Fernandes L, Vaz LG, et al. Microporous zirconium-coated titanium surfaces for dental implant application: Surface characterization, bioactivity and effect on the oral biofilm formation. Journal of Materials Science: Materials in Medicine. 2025. doi:10.1007/s10856-025-06985-1

BibTeX
@article{DelRey2025,
  author = {Del Rey, Yumi C and Albuquerque-Junior, Rubens F and Ramos, Ana Paula and Dos Reis, Bárbara Araújo and Fernandes, Leandro and Vaz, Luis G and do Nascimento, Cássio},
  title = {Microporous zirconium-coated titanium surfaces for dental implant application: Surface characterization, bioactivity and effect on the oral biofilm formation},
  journal = {Journal of Materials Science: Materials in Medicine},
  year = {2025},
  doi = {10.1007/s10856-025-06985-1}
}
Kostenlos starten →