Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs
International Journal of Molecular Sciences · 2023
DOI: 10.3390/ijms241713056 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Sciences, 2023. Verfasst von Elias da Rosa Hoffmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Basic Health Sciences Department, Federal University of Health Sciences of Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil. Hauptthemen laut MEDLINE: Reverse Transcription, COVID-19. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In 2020, a global pandemic caused by SARS-CoV-2 was declared. Different institutes proposed diagnostic molecular methods to detect the virus in clinical samples. This study aims to validate and standardize the use of a loop-mediated isothermal amplification (LAMP)-based methodology targeting the viral RP gene, as a faster and low-cost diagnostic method for SARS-CoV-2 infections. The results obtained with RT-LAMP (Reverse Transcriptase) were compared to the results of real-time polymerase chain reaction (RT-PCR) to assess its sensitivity and specificity. In total, 115 samples (nasopharyngeal samples) were used for detecting SARS-CoV-2 by RT-LAMP, with 43 positives and 72 negatives. The study showed a positive predictive value (PPV) of 90.7% and a negative predictive value (VPN) of 100%. The LAMP assay also demonstrated a high sensitivity of 90.7% and a specificity of 100% (confidence interval 77.9–97.4%) when using the lower detection limit of 40 copies/µL. The RT-LAMP described here has the potential to detect even the new variants of SARS-CoV-2, suggesting that it may not be significantly affected by gene mutations. The RT-LAMP targeting the RP viral region is faster and less expensive than other molecular approaches, making it an alternative for developing countries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Basic Health Sciences Department, Federal University of Health Sciences of Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil.
- Bom Pastor Laboratory, Molecular Biology Department, Igrejinha 95650-000, Brazil.
- Diagnósticos da America S.A., Novo Hamburgo 93520-340, Brazil.
- Central Laboratory, Santa Casa de Misericórdia de Porto Alegre, Porto Alegre 90020-090, Brazil.
- Biomedical Sciences Department, Serra Gaúcha University Center (FSG), Caxias do Sul 95020-472, Brazil.
ORCID-Profile: Elias da Rosa Hoffmann, Guilherme Gaboardi
Zitieren
APA
Hoffmann, E. D. R., Balzan, L. D. R., Inamine, E., Pancotto, L. R., Gaboardi, G., & Cantarelli, V. V. (2023). Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms241713056
Vancouver
Hoffmann EDR, Balzan LDR, Inamine E, Pancotto LR, Gaboardi G, Cantarelli VV. Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs. International Journal of Molecular Sciences. 2023. doi:10.3390/ijms241713056
BibTeX
@article{Hoffmann2023,
author = {Hoffmann, Elias da Rosa and Balzan, Lisiane da Rocha and Inamine, Everton and Pancotto, Lisiane Rech and Gaboardi, Guilherme and Cantarelli, Vlademir Vicente},
title = {Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs},
journal = {International Journal of Molecular Sciences},
year = {2023},
doi = {10.3390/ijms241713056}
}
EUVIMED