EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting

Pornlada Nuchnoi, Pakorn Piromtong, Saranya Siribal, Korrarit Anansilp, Peeradech Thichanpiang, Pilailuk Akkapaiboon Okada

International Journal of Infectious Diseases · 2023

DOI: 10.1016/j.ijid.2023.01.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Infectious Diseases, 2023. Verfasst von Pornlada Nuchnoi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Research and Innovation, Faculty of Medical Technology, Mahidol University, Nakhnon Pathom, Thailand; Department of Clinical Microscopy, F…. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: During the third wave, the growing number of COVID-19 case clusters reported countrywide in Thailand demonstrated the rapidly evolving characteristics of SARS-CoV-2, the causative agent of the COVID-19 pandemic. The rapid spread of COVID-19 infections had been extensively reported in public areas and construction camps, as well as in congested communities with poor sanitation. High demand for SARS-CoV-2 genome testing and quick reporting by an hour for case identification and isolation characterizes the COVID-19 crisis in Thailand. This situation leads to an urgent need for alternative molecular tests which are reliable, rapid, and cost-effective. METHODS: In this study, we assessed colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP), using real-time reverse transcription-polymerase chain reaction (RT-PCR) as a reference standard, for active case finding in suspected (mostly asymptomatic) cases living in high-risk areas of Bangkok. RESULTS: The diagnostic performance of the RT-LAMP compared with real-time RT-PCR in specimens from 549 Thais were computed in a real-world field study setting. Our study demonstrated that RT-LAMP achieved robust identification of SARS-CoV-2 infection, with a diagnostic sensitivity and specificity of 91.67% and 100%, respectively. CONCLUSION: RT-LAMP is a reliable assay for SARS-CoV-2 detection and is scalable for use in the emergency response to a nationwide pandemic, despite resource limitations. The RT-LAMP real-world data derived from this field study validate its potential use in laboratory practice. RT-LAMP is a good choice as a laboratory-based SARS-CoV-2 molecular test when real-time RT-PCR is not available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19HumansReverse TranscriptionPandemicsColorimetryThailandMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesSensitivity and SpecificityRNA, Viral

Stichwörter der Autor:innen

Field evaluationRT-LAMPSARS-COV-2

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • Center for Research and Innovation, Faculty of Medical Technology, Mahidol University, Nakhnon Pathom, Thailand; Department of Clinical Microscopy, Faculty of Medical Technology, Mahidol University, Nakhnon Pathom, Thai…
  • National Institute of Health of Thailand, Department of Medical Sciences, Ministry of Public Health, Nonthaburi, Thailand.
  • Department of Basic Medical Sciences, Faculty of Medicine, Siam University, Bangkok, Thailand.
  • International Center for Medical and Radiological Technology, Faculty of Medical Technology, Mahidol University, Nakhnon Pathom, Thailand.
  • Division of Occupational Therapy, Faculty of Physical Therapy, Mahidol University, Nakhon Pathom, Thailand.

Zitieren

APA

Nuchnoi, P., Piromtong, P., Siribal, S., Anansilp, K., Thichanpiang, P., & Okada, P. A. (2023). Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting. International Journal of Infectious Diseases. https://doi.org/10.1016/j.ijid.2023.01.010

Vancouver

Nuchnoi P, Piromtong P, Siribal S, Anansilp K, Thichanpiang P, Okada PA. Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting. International Journal of Infectious Diseases. 2023. doi:10.1016/j.ijid.2023.01.010

BibTeX
@article{Nuchnoi2023,
  author = {Nuchnoi, Pornlada and Piromtong, Pakorn and Siribal, Saranya and Anansilp, Korrarit and Thichanpiang, Peeradech and Okada, Pilailuk Akkapaiboon},
  title = {Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting},
  journal = {International Journal of Infectious Diseases},
  year = {2023},
  doi = {10.1016/j.ijid.2023.01.010}
}
Kostenlos starten →