Fachartikel in der Zeitschrift International Journal of Environmental Research and Public Health, 2023. Verfasst von Cecilia Vivarelli und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular, Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: INAIL (Italian Workers’ Compensation Authority).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapidly growing worldwide, 5G service is expected to deeply change the way we communicate, connect and share data. It encompasses the whole spectrum of new technology, infrastructure and mobile connectivity, and will touch not only every sector in the industry, but also many aspects of our everyday life. Although the compliance with international regulations provides reasonable protection to public health and safety, there might be specific issues not fully covered by the current technical standards. Among the aspects that shall be carefully considered, there is the potential interference that can be induced on medical devices, and in particular on implantable medical devices that are critical for the patient’s life, such as pacemakers and implantable defibrillators. This study aims to assess the actual risk that 5G communication systems pose to pacemakers and implantable defibrillators. The setup proposed by the ISO 14117 standard was adapted to include 5G characteristic frequencies of 700 MHz and 3.6 GHz. A total number of 384 tests were conducted. Among them, 43 EMI events were observed. Collected results reveal that RF hand-held transmitters operating in these two frequency bands do not pose additional risk compared to pre-5G bands and that the safety distance of 15 cm typically indicted by the PM/ICD manufacturer is still able to guarantee the patient’s safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialHumans

Stichwörter der Autor:innen

5GEMIICDsexposure assessmentpacemakers

Autor:innen und Institutionen

  • Department of Cardiovascular, Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy.
  • Department Ingegneria Civile e Ingegneria Informatica (DICII), University of Rome Tor Vergata, 00133 Rome, Italy.
  • Policlinico Casilino, 00169 Rome, Italy.

ORCID-Profile: Eugenio Mattei

Förderung

  • INAIL (Italian Workers’ Compensation Authority)

Zitieren

APA

Vivarelli, C., Censi, F., Calcagnini, G., De Ruvo, E., Calò, L., & Mattei, E. (2023). 5G Service and Pacemakers/Implantable Defibrillators: What Is the Actual Risk?. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph20054512

Vancouver

Vivarelli C, Censi F, Calcagnini G, De Ruvo E, Calò L, Mattei E. 5G Service and Pacemakers/Implantable Defibrillators: What Is the Actual Risk?. International Journal of Environmental Research and Public Health. 2023. doi:10.3390/ijerph20054512

BibTeX
@article{Vivarelli2023,
  author = {Vivarelli, Cecilia and Censi, Federica and Calcagnini, Giovanni and De Ruvo, Ermenegildo and Calò, Leonardo and Mattei, Eugenio},
  title = {5G Service and Pacemakers/Implantable Defibrillators: What Is the Actual Risk?},
  journal = {International Journal of Environmental Research and Public Health},
  year = {2023},
  doi = {10.3390/ijerph20054512}
}
Kostenlos starten →