A Dynamic Control-Volume Data-Reconciliation Framework for Transient Methane Pyrolysis in a Thermal Plasma Reactor
Hydrogen · 09.11.2026 · 7 (4) · 191
DOI: 10.3390/hydrogen7040191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hydrogen, online erschienen am 09.11.2026. Verfasst von Rafael Segantine und 8 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Eneva H2 Turquoise Project.
Abstract (Originalsprache)
Transient methane pyrolysis in a DC thermal plasma reactor was assessed using a zero-dimensional control-volume reconstruction and elemental balance consistency framework. Programmed Ar and CNG feed rates, time-aligned outlet gas readings, a conditional Ar cross-sensitivity correction for the H2 detector, and finite gas holdup were combined with C/H/O residuals, a lumped thermal state, and exploratory kinetic and exergy scenarios. For the principal 10–25 min interval, the nominal conditional CH4 conversion is 94.2%; the 93.2–95.1% Monte Carlo interval propagates selected nominal analyzer specifications only and is not an experimental confidence interval because the raw H2 readings (approximately 51–59 vol.%; the corrected mean is 59.2 vol.%) exceeded the listed 0–10 vol.% range. Deterministic ±20% H2-channel gain scenarios give 91.95–95.46% conversion but are not calibration-error bounds. A hypothetical air-ingress scenario that closes the mean oxygen balance yields 93.84% conversion with a remaining hydrogen residual of 13.35 mol-H min−1; C2Hγ scenarios do not simultaneously reconcile the hydrogen balance and reported recovered carbonaceous mass. The dynamic and quasi-steady outlet-flow reconstructions nearly coincide (mean ratio: 1.0001; effective gas residence time: ≈0.25 s versus an estimated 1000 s lumped thermal scale). The 4–34 min integrated carbon-equivalent residual is 2.31 kg-C, compared with 1.875 kg of reported recovered carbonaceous material of unverified purity and run attribution. Measured H2 is approximately 49% of the ideal CH4-to-C(s)-plus-2H2 yield, with no unique explanation for the hydrogen deficit. The oxygen residual (−0.143 mol-O/min) is approximately 11.4 times the oxygen input from the stated CNG feed and is therefore not a satisfactory oxygen closure. Reduced kinetic and exergy calculations remain exploratory, assumption-dependent diagnostics, not independently validated performance predictions.
Förderung
- Eneva H2 Turquoise Project
Zitieren
APA
Segantine, R., Miranda, F. D. S., Petraconi, E., Leite, D. M. G., Sobrinho, A. S. D. S., Pessoa, R. S., Kiss’ovski, Z., Essiptchouk, A., & Petraconi, G. (2026). A Dynamic Control-Volume Data-Reconciliation Framework for Transient Methane Pyrolysis in a Thermal Plasma Reactor. Hydrogen, 7(4), 191. https://doi.org/10.3390/hydrogen7040191
Vancouver
Segantine R, Miranda FDS, Petraconi E, Leite DMG, Sobrinho ASDS, Pessoa RS, et al. A Dynamic Control-Volume Data-Reconciliation Framework for Transient Methane Pyrolysis in a Thermal Plasma Reactor. Hydrogen. 2026;7(4):191. doi:10.3390/hydrogen7040191
BibTeX
@article{Segantine2026,
author = {Segantine, Rafael and Miranda, Felipe de Souza and Petraconi, Eduardo and Leite, Douglas Marcel Gonçalves and Sobrinho, Argemiro Soares da Silva and Pessoa, Rodrigo Sávio and Kiss’ovski, Zhivko and Essiptchouk, Alexei and Petraconi, Gilberto},
title = {A Dynamic Control-Volume Data-Reconciliation Framework for Transient Methane Pyrolysis in a Thermal Plasma Reactor},
journal = {Hydrogen},
year = {2026},
volume = {7},
number = {4},
pages = {191},
doi = {10.3390/hydrogen7040191}
}
EUVIMED