EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Post-Ignition Natural-Gas Pyrolysis After Interruption of the Recorded Auxiliary Argon Flow in a Three-Anode Transferred-Arc Reactor

Rafael Segantine, Felipe de Souza Miranda, Eduardo Petraconi, Douglas Leite, Argemiro Soares da Silva Sobrinho, Alexei Essiptchouk, Rodrigo Sávio Pessoa, Gilberto Petraconi

Hydrogen · 03.11.2026 · 7 (4) · 183

DOI: 10.3390/hydrogen7040183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hydrogen, online erschienen am 03.11.2026. Verfasst von Rafael Segantine und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal-plasma methane pyrolysis often uses auxiliary argon during ignition and stabilization. We examined an archived high-throughput run in a three-anode DC transferred-arc reactor, focusing on the response after interruption of the recorded auxiliary-Ar command. The command reached zero at 130.0 min and remained there for 11.67 min while the arc was energized; natural-gas throughput remained near 200 L min−1 for approximately 8 min. A three-minute interval selected by a reproducible stationarity criterion (131–134 min) had a mean natural-gas flow of 197.8 L min−1 and mean arc power of 45.79 kW. The H2 and CH4 analyzer readings gave a 90.31% ratio-derived process indicator. Its mean over the entire eight-minute high-throughput period was 86.1%, declining to approximately 78% by 137.5 min. Under an assumed direct-pyrolysis pathway and the 298.15 K volumetric-flow reference reported by the operator, the reconstructed H2 rate was approximately 1.68 kg h−1, and the arc-power-based specific energy consumption was approximately 27.2 kWh kg−1 H2 (1.84 kg h−1 and 25.0 kWh kg−1 H2 if 273.15 K were used). A calibrated one-step surrogate provided complementary sensitivity analysis. The observations demonstrate sustained high-flow arc operation after the recorded Ar-command interruption. Gas-phase Ar and absolute performance remain conditional on the unmeasured outlet-Ar fraction, the possible protection-gas branch and instrument calibration; the ratio-derived indicator is not an independently closed methane conversion.

Zitieren

APA

Segantine, R., Miranda, F. D. S., Petraconi, E., Leite, D., Sobrinho, A. S. D. S., Essiptchouk, A., Pessoa, R. S., & Petraconi, G. (2026). Post-Ignition Natural-Gas Pyrolysis After Interruption of the Recorded Auxiliary Argon Flow in a Three-Anode Transferred-Arc Reactor. Hydrogen, 7(4), 183. https://doi.org/10.3390/hydrogen7040183

Vancouver

Segantine R, Miranda FDS, Petraconi E, Leite D, Sobrinho ASDS, Essiptchouk A, et al. Post-Ignition Natural-Gas Pyrolysis After Interruption of the Recorded Auxiliary Argon Flow in a Three-Anode Transferred-Arc Reactor. Hydrogen. 2026;7(4):183. doi:10.3390/hydrogen7040183

BibTeX
@article{Segantine2026,
  author = {Segantine, Rafael and Miranda, Felipe de Souza and Petraconi, Eduardo and Leite, Douglas and Sobrinho, Argemiro Soares da Silva and Essiptchouk, Alexei and Pessoa, Rodrigo Sávio and Petraconi, Gilberto},
  title = {Post-Ignition Natural-Gas Pyrolysis After Interruption of the Recorded Auxiliary Argon Flow in a Three-Anode Transferred-Arc Reactor},
  journal = {Hydrogen},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {183},
  doi = {10.3390/hydrogen7040183}
}
Kostenlos starten →