EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of Embedded Cold Plate and Cooling Tissue Wick Sheet on the Electro-Thermal Efficiency of Photovoltaic Panels

A. Siricharoenpanich, P. Vengsungnle, A. Janyalertadun, P. Naphon

Eng · 16.11.2026 · 7 (11) · 648

DOI: 10.3390/eng7110648 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eng, online erschienen am 16.11.2026. Verfasst von A. Siricharoenpanich und 3 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The thermal performance of photovoltaic (PV) modules strongly influences their electrical efficiency, particularly under high solar irradiance conditions. This study experimentally investigates the effectiveness of active and passive cooling strategies for PV modules under real outdoor conditions. Three configurations were evaluated: active water cooling using a cold-plate system (Model I), passive evaporative cooling using a wet tissue layer (Model II), and an uncooled reference module (Model III). All systems were tested simultaneously under identical environmental conditions to enable direct and fair performance comparison. The results show that both cooling methods effectively reduce PV module operating temperature, improving electrical performance. The active water-cooling system achieved the largest temperature reduction, up to 25 °C, resulting in a maximum efficiency of about 12.6%. The passive evaporative system reduced the temperature by about 13 °C, with a corresponding efficiency of about 12.2%, demonstrating a viable, low-cost, energy-efficient alternative. A thermo-hydraulic analysis revealed that the water-cooling system operated under a fully laminar flow regime (Re ≈ 106), with a moderate convective heat transfer coefficient and negligible pumping power, yet sufficient heat removal capacity to suppress thermal accumulation. This study provides a systematic experimental benchmark for comparing PV cooling strategies under identical outdoor conditions and highlights the trade-off between cooling effectiveness and system simplicity. The findings offer practical insights for designing and deploying photovoltaic thermal management systems, particularly in hot-climate regions and building-integrated photovoltaic (BIPV) applications.

Zitieren

APA

Siricharoenpanich, A., Vengsungnle, P., Janyalertadun, A., & Naphon, P. (2026). Effects of Embedded Cold Plate and Cooling Tissue Wick Sheet on the Electro-Thermal Efficiency of Photovoltaic Panels. Eng, 7(11), 648. https://doi.org/10.3390/eng7110648

Vancouver

Siricharoenpanich A, Vengsungnle P, Janyalertadun A, Naphon P. Effects of Embedded Cold Plate and Cooling Tissue Wick Sheet on the Electro-Thermal Efficiency of Photovoltaic Panels. Eng. 2026;7(11):648. doi:10.3390/eng7110648

BibTeX
@article{Siricharoenpanich2026,
  author = {Siricharoenpanich, A. and Vengsungnle, P. and Janyalertadun, A. and Naphon, P.},
  title = {Effects of Embedded Cold Plate and Cooling Tissue Wick Sheet on the Electro-Thermal Efficiency of Photovoltaic Panels},
  journal = {Eng},
  year = {2026},
  volume = {7},
  number = {11},
  pages = {648},
  doi = {10.3390/eng7110648}
}
Kostenlos starten →