Evaluation of North American Standards for Lateral- Torsional Buckling Capacity of Steel I-Beams with Extended Shear Tab Connections
Eng · 08.11.2026 · 7 (11) · 629
DOI: 10.3390/eng7110629 ↗Kurz gefasst
Fachartikel in der Zeitschrift Eng, online erschienen am 08.11.2026. Verfasst von Pronob K. Ghosh und 1 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Concordia University.
Abstract (Originalsprache)
Steel shear tab connections connect beams to columns and girders. While extended shear tab (EST) connections have been studied for stability and strength, their impact on the lateral torsional buckling (LTB) capacity of I-beams has not been explored. To address this research gap, the present study uses finite element (FE) modelling to examine how EST connection details affect the LTB capacity of I-beams. Several parameters, such as shear tab thickness, bolt configurations, unbraced beam length, bolt distance from the supporting member, and stabilizer plates, are examined. Results show that steel stabilizer plates can significantly improve LTB resistance of laterally unsupported I-beams with EST connections, by up to 61% compared to unstiffened connections. However, beams connected through unstiffened ESTs, regardless of whether a single or double vertical bolt arrangement is used, may exhibit substantially lower LTB strengths than those predicted by CSA S16-19 and ANSI/AISC 360-22, particularly in deeper sections. Finally, an alternative connection configuration employing a standard channel section in place of the conventional shear tab plate is also investigated. FE analysis shows that this channel-based detail can improve the LTB capacity of I-beams by about 27% for the W410X54 beam section, compared to standard shear tab connections.
Förderung
- Concordia University
Zitieren
APA
Ghosh, P. K., & Bhowmick, A. K. (2026). Evaluation of North American Standards for Lateral- Torsional Buckling Capacity of Steel I-Beams with Extended Shear Tab Connections. Eng, 7(11), 629. https://doi.org/10.3390/eng7110629
Vancouver
Ghosh PK, Bhowmick AK. Evaluation of North American Standards for Lateral- Torsional Buckling Capacity of Steel I-Beams with Extended Shear Tab Connections. Eng. 2026;7(11):629. doi:10.3390/eng7110629
BibTeX
@article{Ghosh2026,
author = {Ghosh, Pronob K. and Bhowmick, Anjan K.},
title = {Evaluation of North American Standards for Lateral- Torsional Buckling Capacity of Steel I-Beams with Extended Shear Tab Connections},
journal = {Eng},
year = {2026},
volume = {7},
number = {11},
pages = {629},
doi = {10.3390/eng7110629}
}