EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Open-Circuit Fault Diagnosis of Clamping Diodes in Three-Level NPC Inverters Based on Phase Current Asymmetry Index

To Anh Dung, Nguyen Huu Minh, Trinh Trong Chuong, Hoang-Giang Vu

Eng · 11.08.2026 · 7 (8) · 405

DOI: 10.3390/eng7080405 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eng, online erschienen am 11.08.2026. Verfasst von To Anh Dung und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Three-level neutral-point-clamped (NPC) inverters are widely used in medium- and high-power drives and grid-connected applications due to their reduced device voltage stress, improved output power quality, and lower switching losses relative to conventional two-level topologies. Among the potential failure modes, clamping diode open-circuit faults are difficult to detect because the clamping diodes conduct only during the zero-voltage states, and their failure produces only subtle distortions in the phase current waveform. This paper proposes a fault diagnosis method for clamping diode open-circuit faults in three-level NPC inverters. The method is based on a current asymmetry index defined as the ratio of the per-cycle mean phase current to the per-cycle mean absolute phase current. During healthy operation, this index is approximately zero in all phases. A fault causes the index to deviate markedly from zero, while the polarity of this deviation identifies the failed diode. The method requires only phase-current measurements already available in the inverter control system. Consequently, no additional sensors, hardware modifications, or changes to inverter operation are required. Simulation results obtained for a 10 kW three-level NPC inverter demonstrate successful fault detection within approximately one to two fundamental cycles for open-circuit failures of both the upper and lower clamping diodes in all three phases.

Zitieren

APA

Dung, T. A., Minh, N. H., Chuong, T. T., & Vu, H. (2026). Open-Circuit Fault Diagnosis of Clamping Diodes in Three-Level NPC Inverters Based on Phase Current Asymmetry Index. Eng, 7(8), 405. https://doi.org/10.3390/eng7080405

Vancouver

Dung TA, Minh NH, Chuong TT, Vu H. Open-Circuit Fault Diagnosis of Clamping Diodes in Three-Level NPC Inverters Based on Phase Current Asymmetry Index. Eng. 2026;7(8):405. doi:10.3390/eng7080405

BibTeX
@article{Dung2026,
  author = {Dung, To Anh and Minh, Nguyen Huu and Chuong, Trinh Trong and Vu, Hoang-Giang},
  title = {Open-Circuit Fault Diagnosis of Clamping Diodes in Three-Level NPC Inverters Based on Phase Current Asymmetry Index},
  journal = {Eng},
  year = {2026},
  volume = {7},
  number = {8},
  pages = {405},
  doi = {10.3390/eng7080405}
}
Kostenlos starten →