EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cross‐Load Open‐Circuit Fault Diagnosis in Three‐Level NPC Inverters via Period‐Synchronised Windowing

Hüseyin Tayyer Canseven

IET Power Electronics · 2026-01 · 19 (1)

DOI: 10.1049/pel2.70349 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Power Electronics, online erschienen am 17.11.2026. Verfasst von Hüseyin Tayyer Canseven. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data‐driven open‐circuit (OC) fault diagnosis in three‐level neutral‐point‐clamped (NPC) inverters is routinely validated by random cross‐validation on short, overlapped records. A validation‐decomposition protocol separates the two modes such validation conflates, window‐overlap leakage and load distribution shift. On an open dataset (resistive‐inductive load at , induction‐motor load at , OC fault of switch ), leakage proves negligible and distribution shift decisive. On the unseen motor load a support‐vector machine, gradient boosting and a recurrence baseline fall to 0.000, 0.387 and 0.000, the last in 41 of 48 configurations, though four transfer. The descriptors and are period‐antisymmetric, so a partial‐period window biases them toward the fault region. Period‐synchronised windowing removes it, cutting the unseen‐load false‐alarm rate from 0.84 to 0.00 and raising transferring feature pairs from 137 to 374 of 561. Transfer followed shift direction, not magnitude. A single‐sensor detector using one fundamental period ( at ) at per decision matches the full‐feature model, holds to SNR and tolerates frequency error. Residual sensor d.c. offset must stay within of rated peak by zero‐current calibration, not ac‐coupling, which would remove the signature. Findings are feasibility‐level, ranking methods on the observed recordings.

Zitieren

APA

Canseven, H. T. (2026). Cross‐Load Open‐Circuit Fault Diagnosis in Three‐Level NPC Inverters via Period‐Synchronised Windowing. IET Power Electronics, 19(1). https://doi.org/10.1049/pel2.70349

Vancouver

Canseven HT. Cross‐Load Open‐Circuit Fault Diagnosis in Three‐Level NPC Inverters via Period‐Synchronised Windowing. IET Power Electronics. 2026;19(1). doi:10.1049/pel2.70349

BibTeX
@article{Canseven2026,
  author = {Canseven, Hüseyin Tayyer},
  title = {Cross‐Load Open‐Circuit Fault Diagnosis in Three‐Level NPC Inverters via Period‐Synchronised Windowing},
  journal = {IET Power Electronics},
  year = {2026},
  volume = {19},
  number = {1},
  doi = {10.1049/pel2.70349}
}
Kostenlos starten →