One-Year Real-World Effectiveness of a Tubeless Automated Insulin Delivery System in Young Adults with Type 1 Diabetes
Endocrines · 01.07.2026 · 7 (3) · 32
DOI: 10.3390/endocrines7030032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endocrines, online erschienen am 01.07.2026. Verfasst von Giordano Spacco und 10 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Diabetes mellitus
Abstract (Originalsprache)
Background/Objectives: Omnipod 5 is a tubeless automated insulin delivery system integrating continuous glucose monitoring (CGM) with algorithm-driven insulin delivery. Clinical trials and real-world studies have shown improved glycemic control and reduced hypoglycemia in people with type 1 diabetes (T1D) previously treated with multiple daily injections (MDI) or non-automated sensor-augmented pump (SAP) therapy. However, long-term real-world data in young adults remain limited.
Methods
We conducted a retrospective, single-centre observational study including adults with T1D who started therapy with a tubeless automated insulin delivery system (Omnipod 5). Participants were previously treated with MDI or SAP therapy. Glycemic outcomes were assessed using CGM metrics at baseline, 1, 3, and 12 months after starting the system. The primary outcome was change in time in range of 70–180 mg/dL (TIR) at 12 months. Secondary outcomes included additional CGM metrics, insulin therapy parameters, and the occurrence of diabetic ketoacidosis (DKA) and severe hypoglycaemia (SH) episodes.
Results
Fifty-two patients were included (mean age 23.0 ± 4.3 years; diabetes duration 13.8 ± 5.9 years); 51 completed 12-month follow-up. At 12 months, TIR increased from 56.1 ± 11.4% to 67.4 ± 11.0% (+11.3%; p < 0.001), while time in tight range of 70–140 mg/dL (TITR) increased from 34.5 ± 10.9% to 44.8 ± 8.7% (+10.3%; p < 0.001). Time in hypoglycemia also decreased, with no episodes of DKA or SH reported during the study period. Glycemic improvements were evident at 1 month and maintained at 12 months. The proportion of patients achieving recommended targets improved at 12 months, including TIR > 70% (13.5% to 43.1%). Total daily insulin requirements remained unchanged, while basal insulin proportion increased, and daily boluses decreased (both p < 0.001).
Conclusions
In this real-world study, Omnipod 5 therapy was associated with improved glycemic control and reduced hypoglycemia over 12 months in young adults with T1D, without increasing insulin requirements.
Zitieren
APA
Spacco, G., Marcenaro, S., Caporotondi, B., Rosmino, C., Vanorio, B., Siri, G., Calevo, M. G., Gaiero, A., Maghnie, M., Minuto, N., & Bassi, M. (2026). One-Year Real-World Effectiveness of a Tubeless Automated Insulin Delivery System in Young Adults with Type 1 Diabetes. Endocrines, 7(3), 32. https://doi.org/10.3390/endocrines7030032
Vancouver
Spacco G, Marcenaro S, Caporotondi B, Rosmino C, Vanorio B, Siri G, et al. One-Year Real-World Effectiveness of a Tubeless Automated Insulin Delivery System in Young Adults with Type 1 Diabetes. Endocrines. 2026;7(3):32. doi:10.3390/endocrines7030032
BibTeX
@article{Spacco2026,
author = {Spacco, Giordano and Marcenaro, Silvia and Caporotondi, Benedetta and Rosmino, Chiara and Vanorio, Barbara and Siri, Giulia and Calevo, Maria Grazia and Gaiero, Alberto and Maghnie, Mohamad and Minuto, Nicola and Bassi, Marta},
title = {One-Year Real-World Effectiveness of a Tubeless Automated Insulin Delivery System in Young Adults with Type 1 Diabetes},
journal = {Endocrines},
year = {2026},
volume = {7},
number = {3},
pages = {32},
doi = {10.3390/endocrines7030032}
}
EUVIMED