Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 20.11.2026. Verfasst von Yi Lv und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Research Fund of Hubei Technology Innovation Center for Smart Hydropower(2024).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For pumped-storage generator-motors, stator-winding main insulation is subjected to repeated electrical, thermal, and mechanical stresses during frequent operating-mode transitions. To precisely detect the main insulation condition of the stator windings in pumped-storage motors and identify key parameters related to the insulation medium’s conductivity and relaxation processes, this paper proposes a method based on sparse-promoted dynamic mode decomposition of depolarization current. First, the time series of depolarization current is decomposed using dynamic mode decomposition. Then, the optimal amplitude coefficients for different modes are calculated using the alternating direction method of multipliers. This process separates the dominant mode, which represents the relaxation characteristics of the main insulation, from spurious modes representing noise interference. The dominant mode is used to calculate the parameters of the extended Debye model, enabling precise identification of relaxation characteristics. Finally, the proposed method is verified using both preset-model simulations and PDC experiments on stator bars under different thermal aging conditions. The results show that the proposed method can automatically determine the branch number of the extended Debye model and effectively identify the branch parameters related to the relaxation processes of the main insulation, thereby providing dielectric-response parameter support for offline insulation condition assessment of stator windings in pumped-storage generator-motors.

Förderung

  • Open Research Fund of Hubei Technology Innovation Center for Smart Hydropower(2024)

Zitieren

APA

Lv, Y., Zhu, G., Liu, J., Liu, Y., Ma, S., Kong, L., & Cao, S. (2026). An Insulation Condition Assessment Method for Stator Windings of Pumped-Storage Generators Based on Sparsity-Promoting Dynamic Mode Decomposition of Depolarization Current. Energies, 19(22), 5636. https://doi.org/10.3390/en19225636

Vancouver

Lv Y, Zhu G, Liu J, Liu Y, Ma S, Kong L, et al. An Insulation Condition Assessment Method for Stator Windings of Pumped-Storage Generators Based on Sparsity-Promoting Dynamic Mode Decomposition of Depolarization Current. Energies. 2026;19(22):5636. doi:10.3390/en19225636

BibTeX
@article{Lv2026,
  author = {Lv, Yi and Zhu, Guangya and Liu, Jiachen and Liu, Yunchang and Ma, Shiyu and Kong, Lijun and Cao, Shiquan},
  title = {An Insulation Condition Assessment Method for Stator Windings of Pumped-Storage Generators Based on Sparsity-Promoting Dynamic Mode Decomposition of Depolarization Current},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5636},
  doi = {10.3390/en19225636}
}
Kostenlos starten →