EUVIMEDEUVIMED entdecken
Crossref

Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation

Bolun Zhang, Zheng Wang, Zhixiang Zou, Kai Wang, Wanqing Chen, Jian-Xin Shen

IEEE Transactions on Industrial Electronics · 2026-06 · 73 (6) · 8342-8353

DOI: 10.1109/tie.2026.3651396 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2026-06. Verfasst von Bolun Zhang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stator winding insulation is one of the most fragile components in electric drive system. To prevent insulation-related failures, online condition monitoring of stator insulation is critical to ensure high reliability requirements in inverter-fed ac motors. Groundwall insulation monitoring can be achieved by common-mode (CM) measuring methods, which evaluate insulation by CM impedance spectrum shifts. However, CM impedance shows distinct insulation-related characteristics over broadband frequency range. In this article, insulation-related characteristics are revealed and compared by developing individual models in different frequency regions. Besides, a hybrid model-data driven method is proposed to achieve assessment of groundwall insulation in this article. Phase-to-ground and neutral-to-ground insulation are distinguished by pretrained network, which establishes the link between CM features and insulation capacitances. Experimental results have been conducted on inverter-fed induction machine with an accelerated aging procedure. The experiment results prove that the proposed method can achieve detection of groundwall insulation in real time.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Zhang, B., Wang, Z., Zou, Z., Wang, K., Chen, W., & Shen, J. (2026). Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation. IEEE Transactions on Industrial Electronics, 73(6), 8342-8353. https://doi.org/10.1109/tie.2026.3651396

Vancouver

Zhang B, Wang Z, Zou Z, Wang K, Chen W, Shen J. Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation. IEEE Transactions on Industrial Electronics. 2026;73(6):8342-8353. doi:10.1109/tie.2026.3651396

BibTeX
@article{Zhang2026,
  author = {Zhang, Bolun and Wang, Zheng and Zou, Zhixiang and Wang, Kai and Chen, Wanqing and Shen, Jian-Xin},
  title = {Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2026},
  volume = {73},
  number = {6},
  pages = {8342--8353},
  doi = {10.1109/tie.2026.3651396}
}
Kostenlos starten →