EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Generalized Energy–Exergy Performance Evaluation Framework for Integrated Offshore Renewable Energy Systems

Idehai O. Ohijeagbon, Oluwagbenga T. Johnson, Venkateswarlu Kavati, Thomas Alweendo, Odilon K. Ilunga

Energies · 16.11.2026 · 19 (22) · 5531

DOI: 10.3390/en19225531 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 16.11.2026. Verfasst von Idehai O. Ohijeagbon und 4 weiteren Autor:innen. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study develops a Generalized Offshore Renewable Energy Performance Framework (GOREPF) incorporating a Thermodynamic Resource-to-Product Performance Framework (TRPPF) to assess offshore wind, tidal, wave, and floating photovoltaic (FPV) systems on a common energy–exergy basis. Exergy leaving a control volume unconverted is distinguished from exergy destroyed by internal irreversibility, ensuring closed exergy balances. Energy and exergy efficiencies, exergy destruction, and sustainability index (SI) are evaluated under low-, mid-, and high-resource scenarios, alongside levelized cost of energy (LCOE) and life-cycle global warming potential (GWP); formulations for co-located systems are also provided. Under mid-resource conditions, exergy efficiency reaches 42.75% (wind), 38.00% (tidal), 27.60% (wave), and 20.07% (FPV), with SI values of 1.75, 1.61, 1.38, and 1.25, respectively. For wind, tidal, and wave systems, energy and exergy efficiencies are identical, whereas FPV exhibits higher exergy efficiency. Under high-resource conditions, wind efficiency falls to 12.67% because output is capped at rated power, below tidal (16.03%), wave (18.40%), and FPV (19.42%). FPV exhibits the highest exergy destruction (1.15 MW), while wind shows the largest non-converted exergy (6.99 MW). Wind combines the highest exergy efficiency with the lowest LCOE (60 USD/MWh) and GWP intensity (9 g CO2-eq/kWh), whereas FPV exhibits the lowest exergy efficiency and highest GWP intensity (30 g CO2-eq/kWh). Tidal achieves the second-highest exergy efficiency but the highest LCOE (225 USD/MWh). Thermodynamic, economic, and environmental rankings do not necessarily align, and the proposed framework provides a technology-neutral basis for comparative assessment and digital-twin integration.

Zitieren

APA

Ohijeagbon, I. O., Johnson, O. T., Kavati, V., Alweendo, T., & Ilunga, O. K. (2026). A Generalized Energy–Exergy Performance Evaluation Framework for Integrated Offshore Renewable Energy Systems. Energies, 19(22), 5531. https://doi.org/10.3390/en19225531

Vancouver

Ohijeagbon IO, Johnson OT, Kavati V, Alweendo T, Ilunga OK. A Generalized Energy–Exergy Performance Evaluation Framework for Integrated Offshore Renewable Energy Systems. Energies. 2026;19(22):5531. doi:10.3390/en19225531

BibTeX
@article{Ohijeagbon2026,
  author = {Ohijeagbon, Idehai O. and Johnson, Oluwagbenga T. and Kavati, Venkateswarlu and Alweendo, Thomas and Ilunga, Odilon K.},
  title = {A Generalized Energy–Exergy Performance Evaluation Framework for Integrated Offshore Renewable Energy Systems},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5531},
  doi = {10.3390/en19225531}
}
Kostenlos starten →