Research on Multiphysics Coordinated Control Characteristics of 550 kV Fast Circuit Breaker Operating Mechanism and Arc-Extinguishing Chamber
Energies · 11.07.2026 · 19 (14) · 3275
DOI: 10.3390/en19143275 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 11.07.2026. Verfasst von Shaoan Wang und 8 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
With the expansion of the power grid and the high proportion of new energy access, the short-circuit current level of the system is increasingly approaching the breaking limit of the circuit breaker. This paper focuses on the 550 kV fast circuit breaker, using a coupled numerical model of the operating mechanism and arc-extinguishing chamber to investigate the coordinated influence of nozzle turbulence grooves and compression cylinder diameter. It is found that the turbulence groove enhances the exchange of cold and hot airflow by inducing the recirculation zone. The turbulence groove modifies the local nozzle flow field and enhances cold–hot gas mixing, as indicated by the reduced arc-core temperature and gentler radial temperature gradient without affecting the contact motion characteristics. The maximum temperature of the arc core is reduced from 32.5 kK to 31.4 kK, and the pressure attenuation during the critical period of arc extinguishing is effectively delayed. In addition, the diameter of the compression cylinder and the opening characteristics show significant nonlinear coupling characteristics: when the diameter is 70 mm, the arc blowing strength is insufficient, and when the diameter is 90 mm, the pressure gas reaction overload inhibits the opening speed. The comprehensive analysis shows that when the diameter is 80 mm, the pressure accumulation and mechanical characteristics achieve the best balance, and the arc-core temperature is reduced to a minimum of 29 kK. Among the three investigated cylinder diameters, Dc = 80 mm provides the best balance between pressure build-up and operating-mechanism response when combined with the nozzle turbulence groove. This configuration provides more favorable flow-field conditions for long-arcing energy dissipation among the investigated cases. It should be emphasized that this conclusion is limited to the investigated range of Dc = 70–90 mm and should not be regarded as a global optimum.
Zitieren
APA
Wang, S., Zhang, T., Wei, J., Sun, Q., Xu, B., Zhao, L., Zhu, Q., Zhao, J., & Li, X. (2026). Research on Multiphysics Coordinated Control Characteristics of 550 kV Fast Circuit Breaker Operating Mechanism and Arc-Extinguishing Chamber. Energies, 19(14), 3275. https://doi.org/10.3390/en19143275
Vancouver
Wang S, Zhang T, Wei J, Sun Q, Xu B, Zhao L, et al. Research on Multiphysics Coordinated Control Characteristics of 550 kV Fast Circuit Breaker Operating Mechanism and Arc-Extinguishing Chamber. Energies. 2026;19(14):3275. doi:10.3390/en19143275
BibTeX
@article{Wang2026,
author = {Wang, Shaoan and Zhang, Tianbo and Wei, Jianwei and Sun, Qingchao and Xu, Bowen and Zhao, Lumin and Zhu, Qijie and Zhao, Jianlei and Li, Xiangwei},
title = {Research on Multiphysics Coordinated Control Characteristics of 550 kV Fast Circuit Breaker Operating Mechanism and Arc-Extinguishing Chamber},
journal = {Energies},
year = {2026},
volume = {19},
number = {14},
pages = {3275},
doi = {10.3390/en19143275}
}