EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Coordinated Low-Voltage Ride-Through Control of a Flywheel-Assisted Permanent-Magnet Direct-Drive Wind Power System Under Asymmetrical Grid Faults

Dahai Guo, Guangchen Liu, Jianwei Zhang, Guizhen Tian, Sufang Wen, Zicheng He, Yan Wang

Energies · 21.05.2026 · 19 (10) · 2476

DOI: 10.3390/en19102476 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 21.05.2026. Verfasst von Dahai Guo und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address fault-period DC-link overvoltage, the reduction in grid-side active-power regulation margin caused by reactive-current-priority operation, and the double-frequency current fluctuation induced by negative-sequence components under asymmetrical grid faults in a flywheel-assisted permanent-magnet direct-drive wind power system, this paper proposes a coordinated low-voltage ride-through (LVRT) strategy based on DC-link-voltage-threshold partitioning. According to the DC-link voltage level, the operating process is divided into a normal regulation region, a grid-side saturation region, and a flywheel activation region, thereby enabling coordinated regulation between grid-side reactive-current support and flywheel-side active-power absorption. To improve transient smoothness, an anti-windup mechanism together with a bumpless transfer scheme is incorporated into the coordinated control process to suppress integrator saturation and mitigate mode-transition disturbances. In addition, a grid-side proportional–integral–vector resonant controller (PI-VRC) is introduced to improve the suppression of double-frequency current fluctuation under asymmetrical faults and enhance converter capacity utilization. Simulation results show that the proposed strategy can effectively restrain fault-period DC-link voltage rise, improve three-phase current symmetry and grid power quality, and strengthen transient reactive-power support, thereby enhancing the asymmetrical-fault LVRT capability of the system.

Förderung

  • National Key R&D Program of China

Zitieren

APA

Guo, D., Liu, G., Zhang, J., Tian, G., Wen, S., He, Z., & Wang, Y. (2026). Coordinated Low-Voltage Ride-Through Control of a Flywheel-Assisted Permanent-Magnet Direct-Drive Wind Power System Under Asymmetrical Grid Faults. Energies, 19(10), 2476. https://doi.org/10.3390/en19102476

Vancouver

Guo D, Liu G, Zhang J, Tian G, Wen S, He Z, et al. Coordinated Low-Voltage Ride-Through Control of a Flywheel-Assisted Permanent-Magnet Direct-Drive Wind Power System Under Asymmetrical Grid Faults. Energies. 2026;19(10):2476. doi:10.3390/en19102476

BibTeX
@article{Guo2026,
  author = {Guo, Dahai and Liu, Guangchen and Zhang, Jianwei and Tian, Guizhen and Wen, Sufang and He, Zicheng and Wang, Yan},
  title = {Coordinated Low-Voltage Ride-Through Control of a Flywheel-Assisted Permanent-Magnet Direct-Drive Wind Power System Under Asymmetrical Grid Faults},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {10},
  pages = {2476},
  doi = {10.3390/en19102476}
}
Kostenlos starten →