An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults
IEEE Transactions on Sustainable Energy · 2024-07 · 15 (3) · 1589-1600
DOI: 10.1109/tste.2024.3358394 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Sustainable Energy, 2024-07. Verfasst von Rui Luo und 3 weiteren Autor:innen. Die Arbeit wurde bisher 45-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Royal Society.
Abstract (Originalsprache)
Existing low-voltage ride-through (LVRT) methods of virtual synchronous generators (VSGs) are facing the problem of inverter damage due to prolonged overcurrent caused by the delay in fault detection. Additionally, the newly updated grid codes (GCs) mandate that inverter-based resources (IBRs) should inject negative-sequence current during asymmetrical faults. To address this issue while complying with the new GCs, this article proposes an adaptive LVRT method. At the onset of the fault, the proposed method compensates for the voltage difference between the reference and feedback values of voltage control loop, while simultaneously adjusting the angle output of the active power loop based on the phase change of the point of connection (POC) voltage and the active power output of the VSG. Thus, it enables a seamless transition between normal and LVRT conditions. Furthermore, it complies with the new GCs and guarantees the maximum utilization of the phase current. The method offers two notable advantages. First, it can achieve fast fault current limitation without the need for fault detection. Second, it eliminates the necessity for parameter design, making it straightforward to implement. The simulation results in PSCAD confirm the effectiveness of the proposed method under different asymmetrical fault conditions.
Förderung
- National Natural Science Foundation of China
- Royal Society
Zitieren
APA
Luo, R., Gao, H., Peng, F., & Guo, Y. (2024). An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults. IEEE Transactions on Sustainable Energy, 15(3), 1589-1600. https://doi.org/10.1109/tste.2024.3358394
Vancouver
Luo R, Gao H, Peng F, Guo Y. An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults. IEEE Transactions on Sustainable Energy. 2024;15(3):1589-1600. doi:10.1109/tste.2024.3358394
BibTeX
@article{Luo2024,
author = {Luo, Rui and Gao, Houlei and Peng, Fang and Guo, Yifei},
title = {An Adaptive Low-Voltage Ride-Through Method for Virtual Synchronous Generators During Asymmetrical Grid Faults},
journal = {IEEE Transactions on Sustainable Energy},
year = {2024},
volume = {15},
number = {3},
pages = {1589--1600},
doi = {10.1109/tste.2024.3358394}
}
EUVIMED