Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder

Nikolaos Mavrikakis, Kiriakos Siderakis

Energies · 12.05.2026 · 19 (10) · 2325

DOI: 10.3390/en19102325 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 12.05.2026. Verfasst von Nikolaos Mavrikakis und 1 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A condition assessment of a group of field-aged insulators operated for only 6 years on the island of Rhodes after incidents of intense electrical activity is presented in this paper. The investigated insulators were in service in 150 kV overhead transmission lines operating in proximity to the seacoast, exposed to the action of marine pollution. Although the same type of insulator has been widely used in similar conditions, both on the island of Rhodes and on the island of Crete, incidents of intense electrical activity have only been experienced in a specific area on the southwest side of Rhodes. To understand the deterioration mechanism, in addition to a group of failed insulators, a number of insulators from the same area without indication of deterioration were removed to be tested. In total, 40 insulators were examined: 23 with extensive failure, three without any deterioration and 14 with different levels of tracking and erosion traces along the polymeric housing. A series of tests were performed, including visual inspection, hydrophobicity classification, insulation performance through tanδ measurements, an adhesion test between the polymeric housing and the rod and material identification of the housing material through FTIR-ATR. The results indicate that the main failure mechanism is insulator flashunder due to the poor adhesion between the polymeric housing and the rod, as well as the poor sealing of insulators, favoring the ingress of water on the insulator rod and the initiation of electrical discharges.

Zitieren

APA

Mavrikakis, N., & Siderakis, K. (2026). Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder. Energies, 19(10), 2325. https://doi.org/10.3390/en19102325

Vancouver

Mavrikakis N, Siderakis K. Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder. Energies. 2026;19(10):2325. doi:10.3390/en19102325

BibTeX
@article{Mavrikakis2026,
  author = {Mavrikakis, Nikolaos and Siderakis, Kiriakos},
  title = {Condition Assessment of Field-Aged Composite Insulators Following Incidents of Insulator Flashunder},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {10},
  pages = {2325},
  doi = {10.3390/en19102325}
}