EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network

Song Zhang, Xiaobin Xiao, Lei Jia, Huaifei Chen, Lu Qu, Chakhung Yeung, Yuxuan Ding, Yaping Du

Energies · 25.09.2025 · 18 (19) · 5097

DOI: 10.3390/en18195097 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 25.09.2025. Verfasst von Song Zhang und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Southern Power Grid.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards.

Förderung

  • China Southern Power Grid

Zitieren

APA

Zhang, S., Xiao, X., Jia, L., Chen, H., Qu, L., Yeung, C., Ding, Y., & Du, Y. (2025). Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network. Energies, 18(19), 5097. https://doi.org/10.3390/en18195097

Vancouver

Zhang S, Xiao X, Jia L, Chen H, Qu L, Yeung C, et al. Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network. Energies. 2025;18(19):5097. doi:10.3390/en18195097

BibTeX
@article{Zhang2025,
  author = {Zhang, Song and Xiao, Xiaobin and Jia, Lei and Chen, Huaifei and Qu, Lu and Yeung, Chakhung and Ding, Yuxuan and Du, Yaping},
  title = {Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {19},
  pages = {5097},
  doi = {10.3390/en18195097}
}
Kostenlos starten →