Unified Open-Phase Fault Diagnosis of Five-Phase PMSM System in Normal Operation and Fault-Tolerant Operation Modes
IEEE Transactions on Transportation Electrification · 2025-10 · 11 (5) · 12063-12075
DOI: 10.1109/tte.2025.3584777 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Transportation Electrification, 2025-10. Verfasst von Xiaolong Xu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, University of Anhui Province through the Outstanding Youth Research Project, Outstanding Youth Project of Natural Science Foundation of Anhui Province.
Abstract (Originalsprache)
The open-phase fault (OPF) is a common electrical fault of five-phase permanent magnet synchronous motor (PMSM) system. The OPF not only can occur in normal operation mode but also in the fault-tolerant operation mode. Hence, this article proposes a unified OPF diagnosis method for five-phase PMSM system in multiple operation modes (normal operation and fault-tolerant operation modes). The proposed method includes two steps: fault detection and fault location. In multiple operation modes, the fault detection can be uniformly achieved by a single-fault indicator, and fault location can be uniformly implemented by space current vector, reducing the fault diagnosis complexity. Both the simulation and experimental results show that the proposed method can achieve unified OPF diagnosis of five-phase PMSM system in multiple operating modes. In addition, the proposed method has the strong robustness to the speed and load disturbance.
Förderung
- National Natural Science Foundation of China
- University of Anhui Province through the Outstanding Youth Research Project
- Outstanding Youth Project of Natural Science Foundation of Anhui Province
- University Synergy Innovation Program of Anhui Province
- Anhui Provincial Major Science and Technology Project
Zitieren
APA
Xu, X., Hang, J., Cao, K., Ding, S., & Wang, W. (2025). Unified Open-Phase Fault Diagnosis of Five-Phase PMSM System in Normal Operation and Fault-Tolerant Operation Modes. IEEE Transactions on Transportation Electrification, 11(5), 12063-12075. https://doi.org/10.1109/tte.2025.3584777
Vancouver
Xu X, Hang J, Cao K, Ding S, Wang W. Unified Open-Phase Fault Diagnosis of Five-Phase PMSM System in Normal Operation and Fault-Tolerant Operation Modes. IEEE Transactions on Transportation Electrification. 2025;11(5):12063-12075. doi:10.1109/tte.2025.3584777
BibTeX
@article{Xu2025,
author = {Xu, Xiaolong and Hang, Jun and Cao, Kai and Ding, Shichuan and Wang, Wei},
title = {Unified Open-Phase Fault Diagnosis of Five-Phase PMSM System in Normal Operation and Fault-Tolerant Operation Modes},
journal = {IEEE Transactions on Transportation Electrification},
year = {2025},
volume = {11},
number = {5},
pages = {12063--12075},
doi = {10.1109/tte.2025.3584777}
}
EUVIMED