EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers

Song Gao, Kaikai Zhang, Xin Jin, Hui Wang, Zengjie Zhao, Huan Wang

Electronics · 2026-08-12 · 15 (16) · 3582

DOI: 10.3390/electronics15163582 ↗

At a glance

Journal article in Electronics, published online on 2026-08-12. Written by Song Gao and 5 co-authors. 41 references. The full text is freely available (open access, CC BY 4.0). Funded by: Natural Science Foundation of Henan Province, Program for Science and Technology Innovation Talents in the University of Henan Province.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

High-voltage vacuum circuit breakers are critical switching devices in power systems, and their reliable condition assessment is essential for safe operation and maintenance decision-making. However, breaker abnormalities are often reflected by heterogeneous operation-related evidence, and existing methods based on single-source measurements or generic feature fusion may weaken source-specific diagnostic roles and limit the recognition of compound abnormal conditions. To address this problem, this paper proposes the Physics-Guided Multi-Source State Assessment Network (PMSA-Net), a reliability-aware framework that integrates mechanical motion, opening- and closing-position limit events, and infrared thermography. Source-specific encoders first extract dynamic, end-position, and thermal representations. Reliability-aware Asymmetric Selective Interaction (RASI) then calibrates primary and auxiliary evidence, using mechanical motion as the operational context and the other sources as complementary constraints. Thermal Frequency-aware Selective Modulation (TFSM) stabilizes the low-frequency thermal field and enhances high-frequency hotspot responses. Task-conditioned evidence allocation jointly predicts state category, travel anomaly, limit-event consistency, thermal risk, and overall risk. On a laboratory-simulated benchmark covering 15 operating conditions, PMSA-Net achieved 90.18±0.36% state-category accuracy and an 80.00±0.50% overall-risk macro-F1 score over five independent runs. Under cross-source abnormalities, it exceeded the variational-fusion baseline by 2.59 and 3.05 percentage points on these metrics, respectively. These results indicate that reliability-aware calibration improves multi-task assessment of compound breaker abnormalities.

Funding

  • Natural Science Foundation of Henan Province
  • Program for Science and Technology Innovation Talents in the University of Henan Province

Cite

APA

Gao, S., Zhang, K., Jin, X., Wang, H., Zhao, Z., & Wang, H. (2026). Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers. Electronics, 15(16), 3582. https://doi.org/10.3390/electronics15163582

Vancouver

Gao S, Zhang K, Jin X, Wang H, Zhao Z, Wang H. Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers. Electronics. 2026;15(16):3582. doi:10.3390/electronics15163582

BibTeX
@article{Gao2026,
  author = {Gao, Song and Zhang, Kaikai and Jin, Xin and Wang, Hui and Zhao, Zengjie and Wang, Huan},
  title = {Motion-to-Risk: Physics-Guided Multi-Source State Assessment for High-Voltage Vacuum Circuit Breakers},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {16},
  pages = {3582},
  doi = {10.3390/electronics15163582}
}
Start for free →